Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/88778
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDas, Dhimanen
dc.contributor.authorSivasubramanian, Kathyayinien
dc.contributor.authorYang, Chunen
dc.contributor.authorPramanik, Manojiten
dc.date.accessioned2018-04-25T08:57:35Zen
dc.date.accessioned2019-12-06T17:10:44Z-
dc.date.available2018-04-25T08:57:35Zen
dc.date.available2019-12-06T17:10:44Z-
dc.date.copyright2018en
dc.date.issued2018en
dc.identifier.citationDas, D., Sivasubramanian, K., Yang, C., & Pramanik, M. (2018). On-chip generation of microbubbles in photoacoustic contrast agents for dual modal ultrasound/photoacoustic in vivo animal imaging. Scientific Reports, 8, 6401-.en
dc.identifier.urihttps://hdl.handle.net/10356/88778-
dc.description.abstractDual-modal photoacoustic (PA) and ultrasound (US) contrast agents are becoming increasingly popular in recent years. Here, a flow-focusing junction based microfluidic device is used for the generation of nitrogen microbubbles (<7 μm) in two photoacoustic contrast agents: methylene blue (MB) and black ink (BI). The microbubble diameter and production rate could be precisely controlled in both MB and BI solutions. Microbubbles were collected from the outlet of the microfluidic device and optical microscope was used to study the size distributions in both solutions. Next, the microbubbles in both solutions were injected into tubes for phantom imaging experiments. Signal to noise ratio (SNR) of both US, PA imaging experiments were calculated to be 51 dB, 58 dB in MB + microbubbles and 56 dB, 61 dB in BI + microbubbles, respectively. Finally, the microbubbles were injected into the urinary bladder of rats for in vivo animal imaging. The SNR in US imaging with MB + microbubbles and BI + microbubbles were 41 dB and 48 dB, respectively. Similarly, the SNR in PA imaging with the same solutions were 32 dB and 36 dB, respectively. The effect of size and concentration of microbubbles in both MB and BI solutions, on the US and PA signals, has been examined.en
dc.description.sponsorshipMOE (Min. of Education, S’pore)en
dc.format.extent10 p.en
dc.language.isoenen
dc.relation.ispartofseriesScientific Reportsen
dc.rights© 2018 The Author(s). This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. Te images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.en
dc.subjectImaging Techniquesen
dc.subjectBiomedical Engineeringen
dc.titleOn-chip generation of microbubbles in photoacoustic contrast agents for dual modal ultrasound/photoacoustic in vivo animal imagingen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Chemical and Biomedical Engineeringen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen
dc.identifier.doi10.1038/s41598-018-24713-4en
dc.description.versionPublished versionen
dc.identifier.rims206342en
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:MAE Journal Articles

SCOPUSTM   
Citations 10

18
Updated on Sep 2, 2020

PublonsTM
Citations 10

18
Updated on Mar 6, 2021

Page view(s)

333
Updated on May 26, 2022

Download(s) 50

62
Updated on May 26, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.