Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/88859
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Popa-Cherecheanu, Alina | en |
dc.contributor.author | Schmidl, Doreen | en |
dc.contributor.author | Werkmeister, René M. | en |
dc.contributor.author | Chua, Jacqueline | en |
dc.contributor.author | Garhöfer, Gerhard | en |
dc.contributor.author | Schmetterer, Leopold | en |
dc.date.accessioned | 2019-02-11T08:33:23Z | en |
dc.date.accessioned | 2019-12-06T17:12:33Z | - |
dc.date.available | 2019-02-11T08:33:23Z | en |
dc.date.available | 2019-12-06T17:12:33Z | - |
dc.date.issued | 2019 | en |
dc.identifier.citation | Popa-Cherecheanu, A., Schmidl, D., Werkmeister, R. M., Chua, J., Garhöfer, G., & Schmetterer, L. (2019). Regulation of Choroidal Blood Flow During Isometric Exercise at Different Levels of Intraocular Pressure. Investigative Opthalmology & Visual Science, 60(1), 176-. doi:10.1167/iovs.18-24992 | en |
dc.identifier.issn | 0146-0404 | en |
dc.identifier.uri | https://hdl.handle.net/10356/88859 | - |
dc.description.abstract | Purpose: There is evidence that choroidal blood flow (ChBF) is regulated in a complex way during changes in ocular perfusion pressure (OPP). We hypothesized that ChBF regulates better in response to changes in mean arterial pressure (MAP) than in intraocular pressure (IOP). Methods: Eighteen volunteers (mean age, 26 years) were recruited for a randomized, three-way crossover design. MAP was varied via isometric exercise. IOP was either kept normal or elevated by 10 or 20 mm Hg by using a suction cup. Subfoveal ChBF was measured continuously for 8 minutes with laser Doppler flowmetry and OPP was calculated as 2/3*MAP-IOP. For data analysis, values from all subjects were pooled according to either IOP or MAP values, and correlation analyses were done. Results: When data were grouped according to IOP, no correlation was observed between ChBF and MAP, but ChBF was lower the higher the IOP (P < 0.001). When data were grouped according to MAP, a significant correlation was found between ChBF and IOP (P < 0.001). When data were pooled according to IOP, the correlation between ChBF and OPP was weaker (P < 0.05). The OPP at which ChBF significantly increased from baseline was 61.3% ± 4.9% without suction cup, 65.2% ± 3.5% when IOP was increased by 10 mm Hg, and slightly lower when IOP was increased by 20 mm Hg (56.3% ± 4.8%, P = 0.07), but this effect did not reach the level of significance. Conclusions: The present study provides further evidence that the regulation of ChBF during changes in OPP is controlled by complex mechanisms in humans and has less capacity to adapt to IOP elevation than to MAP increase. | en |
dc.format.extent | 7 p. | en |
dc.language.iso | en | en |
dc.relation.ispartofseries | Investigative Opthalmology & Visual Science | en |
dc.rights | © 2019 The Authors. This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | en |
dc.subject | DRNTU::Science::Medicine | en |
dc.subject | Ocular Perfusion Pressure | en |
dc.subject | Choroidal Blood Flow | en |
dc.title | Regulation of choroidal blood flow during isometric exercise at different levels of intraocular pressure | en |
dc.type | Journal Article | en |
dc.contributor.school | Lee Kong Chian School of Medicine (LKCMedicine) | en |
dc.identifier.doi | 10.1167/iovs.18-24992 | en |
dc.description.version | Published version | en |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
Appears in Collections: | LKCMedicine Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Regulation of Choroidal Blood Flow During Isometric Exercise at Different Levels of Intraocular Pressure.pdf | 724.27 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
50
7
Updated on Mar 21, 2024
Web of ScienceTM
Citations
20
7
Updated on Oct 24, 2023
Page view(s) 50
472
Updated on Mar 28, 2024
Download(s) 50
112
Updated on Mar 28, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.