Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/88880
Title: | Wavelength-flattened directional coupler based mid-infrared chemical sensor using bragg wavelength in subwavelength grating structure | Authors: | Dong, Bowei Hu, Ting Luo, Xianshu Chang, Yuhua Guo, Xin Wang, Hong Kwong, Dim-Lee Lo, Guo-Qiang Lee, Chengkuo |
Keywords: | Photonics Sensors Nanophotonics DRNTU::Engineering::Electrical and electronic engineering |
Issue Date: | 2018 | Source: | Dong, B., Hu, T., Luo, X., Chang, Y., Guo, X., Wang, H., Kwong, D.-L., et al. (2018). Wavelength-Flattened Directional Coupler Based Mid-Infrared Chemical Sensor Using Bragg Wavelength in Subwavelength Grating Structure. Nanomaterials, 8(11), 893-. doi:10.3390/nano8110893 | Series/Report no.: | Nanomaterials | Abstract: | In this paper, we report a compact wavelength-flattened directional coupler (WFDC) based chemical sensor featuring an incorporated subwavelength grating (SWG) structure for the mid-infrared (MIR). By incorporating a SWG structure into directional coupler (DC), the dispersion in DC can be engineered to allow broadband operation which is advantageous to extract spectroscopic information for MIR sensing analysis. Meanwhile, the Bragg reflection introduced by the SWG structure produces a sharp trough at the Bragg wavelength. This sharp trough is sensitive to the surrounding refractive index (RI) change caused by the existence of analytes. Therefore, high sensitivity can be achieved in a small footprint. Around fivefold enhancement in the operation bandwidth compared to conventional DC is achieved for 100% coupling efficiency in a 40 µm long WFDC experimentally. Detection of dichloromethane (CH2Cl2) in ethanol (C2H5OH) is investigated in a SWG-based WFDC sensor 136.8 µm long. Sensing performance is studied by 3D finite-difference time domain (FDTD) simulation while sensitivity is derived by computation. Both RI sensing and absorption sensing are examined. RI sensing reveals a sensitivity of −0.47% self-normalized transmitted power change per percentage of CH2Cl2 concentration while 0.12% change in the normalized total integrated output power is realized in the absorption sensing. As the first demonstration of the DC based sensor in the MIR, our device has the potential for tertiary mixture sensing by utilizing both changes in the real and imaginary part of RI. It can also be used as a broadband building block for MIR application such as spectroscopic sensing system. | URI: | https://hdl.handle.net/10356/88880 http://hdl.handle.net/10220/46978 |
ISSN: | 2079-4991 | DOI: | 10.3390/nano8110893 | Schools: | School of Electrical and Electronic Engineering | Rights: | © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Wavelength-Flattened Directional Coupler Based Mid-Infrared Chemical Sensor Using Bragg Wavelength in Subwavelength Grating Structure.pdf | 3.05 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
10
40
Updated on Dec 1, 2023
Web of ScienceTM
Citations
10
36
Updated on Oct 25, 2023
Page view(s) 50
489
Updated on Dec 7, 2023
Download(s) 50
86
Updated on Dec 7, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.