Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/89244
Title: | Effects of water related factors on pre-grouting in hard rock tunnelling | Authors: | Mao, Dawei Lu, Ming Zhao, Zhiye Ng, Melvin |
Keywords: | Inflow DRNTU::Engineering::Civil engineering Water Control |
Issue Date: | 2016 | Source: | Mao, D., Lu, M., Zhao, Z., & Ng, M. (2016). Effects of Water Related Factors on Pre-grouting in Hard Rock Tunnelling. Procedia Engineering, 165, 300-307. doi : 10.1016/j.proeng.2016.11.704 | Series/Report no.: | Procedia Engineering | Abstract: | Water control is highly concerned for underground facilities, and rock grouting has been used over decades to reduce the water inflow. The performances of grouting are influenced by many factors such as rock type, joint distribution and grouting materials. In this paper, the effects of water related factors are focused, from the engineering perspective. The observed volume of water inflow from the probe drilling hole often serves as the base for judgment of grouting needs. The allowable limit of water inflow varies for underground facilities of different purposes. For similar underground facilities, such limit may also differ substantially in different regions. High pressure of underground water would increase difficulty for grouting. The water appearance may give indication on whether the fillings of joints or the weakness zones have been eroded. In the coastal area, the inflow water can be saline, and this needs to be taken into consideration to eliminate corrosion on electrical installations underground. | URI: | https://hdl.handle.net/10356/89244 http://hdl.handle.net/10220/46197 |
ISSN: | 1877-7058 | DOI: | 10.1016/j.proeng.2016.11.704 | Schools: | School of Civil and Environmental Engineering | Rights: | © 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (https://creativecommons.org/licenses/by-nc-nd/4.0/). Selection and/or peer-review under responsibility of the scientific committee of Symposium 2015 ICMAT | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | CEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Effects of Water Related Factors on Pre-grouting in Hard Rock Tunnelling.pdf | 526.36 kB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
20
17
Updated on Mar 13, 2025
Web of ScienceTM
Citations
20
11
Updated on Oct 30, 2023
Page view(s) 50
538
Updated on Mar 18, 2025
Download(s) 50
144
Updated on Mar 18, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.