Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/89282
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Li, Yuanlong | en |
dc.contributor.author | Wen, Yonggang | en |
dc.contributor.author | Wah Wong, Yew | en |
dc.contributor.author | Chuan Toh, Kok | en |
dc.contributor.author | Jiao, Yanmei | en |
dc.contributor.author | Cheng Chua, Chee | en |
dc.contributor.author | Ang, Wilson | en |
dc.date.accessioned | 2018-10-02T09:10:28Z | en |
dc.date.accessioned | 2019-12-06T17:21:54Z | - |
dc.date.available | 2018-10-02T09:10:28Z | en |
dc.date.available | 2019-12-06T17:21:54Z | - |
dc.date.issued | 2017 | en |
dc.identifier.citation | Jiao, Y., Li, Y., Wen, Y., Wong, Y. W., Toh, K. C., Chua, C. C., & Ang, W. (2017). Thermal Analysis for Underground Data Centres in the Tropics. Energy Procedia, 143, 223-229. doi : 10.1016/j.egypro.2017.12.675 | en |
dc.identifier.issn | 1876-6102 | en |
dc.identifier.uri | https://hdl.handle.net/10356/89282 | - |
dc.description.abstract | Different with traditional aboveground data centres, underground data centres have attracted increasing attention during recent years due to its inherent geographical advantages such as zero solar heat gain, low ambient temperature, natural geothermal cooling, and solid rock surrounded structures. The energy reduction in air-conditioning and mechanical ventilation (ACMV) system of the underground data centre is even more significant for the tropical regions where air is hot and humid all the year round. However, little study has been conducted to systematically analyse the relationship between the air-conditioning effectiveness and the corresponding energy efficiency. In this work, both energy simulations and computational fluid dynamics (CFD) simulations are conducted to the underground air-conditioning data centres in the tropics. The former one studies the energy consumption and energy efficiency of the whole ACMV system for a data centre. Meanwhile, the latter one studies the corresponding detailed airflow pattern within the data centre room. Optimizations in air management of the ACMV system are also proposed based on the energy and CFD simulation results. | en |
dc.format.extent | 7 p. | en |
dc.language.iso | en | en |
dc.relation.ispartofseries | Energy Procedia | en |
dc.rights | © 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the World Engineers Summit – Applied Energy Symposium & Forum: Low Carbon Cities & Urban Energy Joint Conference. | en |
dc.subject | DRNTU::Engineering::Computer science and engineering | en |
dc.subject | ACMV System | en |
dc.subject | Underground Data Centre | en |
dc.title | Thermal analysis for underground data centres in the tropics | en |
dc.type | Journal Article | en |
dc.contributor.school | School of Computer Science and Engineering | en |
dc.contributor.research | Energy Research Institute @ NTU (ERI@N) | en |
dc.contributor.research | Temasek Laboratories | en |
dc.identifier.doi | 10.1016/j.egypro.2017.12.675 | en |
dc.description.version | Published version | en |
item.grantfulltext | open | - |
item.fulltext | With Fulltext | - |
Appears in Collections: | SCSE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Thermal Analysis for Underground Data Centres in the Tropics.pdf | 1.2 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
50
1
Updated on Mar 18, 2023
Web of ScienceTM
Citations
50
4
Updated on Mar 14, 2023
Page view(s)
330
Updated on Mar 24, 2023
Download(s) 50
113
Updated on Mar 24, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.