Title: | Dynamic modeling and validation of a liquid desiccant cooling and dehumidification system | Authors: | Ou, Xianhua Cai, Wenjian He, Xiongxiong Zhai, Deqing Wang, Xinli |
Keywords: | Cooling Coil Dehumidifier |
Issue Date: | 2017 | Source: | Ou, X., Cai, W., He, X., Zhai, D., & Wang, X. (2018). Dynamic modeling and validation of a liquid desiccant cooling and dehumidification system. Energy and Buildings, 163, 44-57. | Series/Report no.: | Energy and Buildings | Abstract: | In this study, a simplified dynamic model for the liquid desiccant cooling and dehumidification system (LDCDS) is developed from a control viewpoint based on the laws of conservation of energy and mass. The complete LDCDS consists of three subsystems, namely the cooling coil, dehumidifier and cooler in which the models can be estimated separately and combined to obtain the model of LDCDS. The heat and mass transfer rates in model are derived through effectiveness-NTU and hybrid modeling approaches. The parameters of the thermal and moisture dynamic models are pre-identified by using the Levenberg–Marquardt method with static experimental data from the LDCDS pilot plant and then refined by adopting an unscented Kalman filter algorithm with dynamic experimental data. Detailed experimental tests on a pilot plant reveal that the proposed model accurately predicts the system performance under different operating conditions. The proposed model is expected to be applied in further research on the effects of more advanced control and optimization algorithms with the system energy efficiency. | URI: | https://hdl.handle.net/10356/89303 http://hdl.handle.net/10220/44879 |
ISSN: | 0378-7788 | DOI: | 10.1016/j.enbuild.2017.12.041 | Schools: | School of Electrical and Electronic Engineering | Research Centres: | Centre for System Intelligence and Efficiency (EXQUISITUS) | Rights: | © 2017 Elsevier B.V. This is the author created version of a work that has been peer reviewed and accepted for publication by Energy and Buildings, Elsevier B.V. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.enbuild.2017.12.041]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Dynamic modeling and validation of a liquid desiccant.pdf | 5.02 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
20
17
Updated on May 3, 2025
Web of ScienceTM
Citations
20
13
Updated on Oct 27, 2023
Page view(s) 10
1,020
Updated on May 5, 2025
Download(s) 20
372
Updated on May 5, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.