Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/91257
Title: | Pulsed laser diode based desktop photoacoustic tomography for monitoring wash-in and wash-out of dye in rat cortical vasculature | Authors: | Kalva, Sandeep Kumar Upputuri, Paul Kumar Rajendran, Praveenbalaji Dienzo, Rhonnie Austria Pramanik, Manojit |
Keywords: | Acoustic Reflector Bioengineering DRNTU::Engineering::Chemical engineering |
Issue Date: | 2019 | Source: | Kalva, S. K., Upputuri, P. K., Rajendran, P., Dienzo, R. A., & Pramanik, M. (2019). Pulsed laser diode based desktop photoacoustic tomography for monitoring wash-in and wash-out of dye in rat cortical vasculature. Journal of Visualized Experiments, (147). doi:10.3791/59764 | Series/Report no.: | Journal of Visualized Experiments | Abstract: | Photoacoustic (PA) tomography (PAT) imaging is an emerging biomedical imaging modality useful in various preclinical and clinical applications. Custom-made circular ring array-based transducers and conventional bulky Nd:YAG/OPO lasers inhibit translation of the PAT system to clinics. Ultra-compact pulsed laser diodes (PLDs) are currently being used as an alternative source of near-infrared excitation for PA imaging. Highspeed dynamic in vivo imaging has been demonstrated using a compact PLD-based desktop PAT system (PLD-PAT). A visualized experimental protocol using the desktop PLD-PAT system is provided in this work for dynamic in vivo brain imaging. The protocol describes the desktop PLDPAT system configuration, preparation of animal for brain vascular imaging, and procedure for dynamic visualization of indocyanine green (ICG) dye uptake and clearance process in rat cortical vasculature. | URI: | https://hdl.handle.net/10356/91257 http://hdl.handle.net/10220/48791 |
DOI: | 10.3791/59764 | Schools: | School of Chemical and Biomedical Engineering | Rights: | © 2019 The Author(s) (Journal of Visualized Experiments). All rights reserved. This paper was published in Journal of Visualized Experiments and is made available with permission of The Author(s) (Journal of Visualized Experiments). | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | SCBE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Pulsed-laser-diode-based-desktop-photoacoustic-tomography-for monitoring wash-in and wash-out of dye in rat cortical vasculature.pdf | 259.73 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
50
7
Updated on Mar 13, 2024
Web of ScienceTM
Citations
50
5
Updated on Oct 24, 2023
Page view(s) 50
515
Updated on Mar 18, 2024
Download(s) 50
125
Updated on Mar 18, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.