Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/94115
Title: Low-pressure, high-temperature thermal bonding of polymeric microfluidic devices and their applications for electrophoretic separation
Authors: Sun, Yi
Kwok, Yien Chian
Nguyen, Nam-Trung
Keywords: DRNTU::Engineering::Mechanical engineering
Issue Date: 2006
Source: Sun, Y., Kwok, Y. C., & Nguyen, N. T. (2006). Low-pressure, high-temperature thermal bonding of polymeric microfluidic devices and their applications for electrophoretic separation. Journal of Micromechanics and Microengineering, 16(8).
Series/Report no.: Journal of micromechanics and microengineering
Abstract: A new method for thermally bonding poly(methyl methacrylate) (PMMA) substrates has been demonstrated. PMMA substrates are first engraved by CO2-laser micromachining to form microchannels. Both channel width and depth can be adjusted by varying the laser power and scanning speed. Channel depths from 50 µm to 1500 µm and widths from 150 µm to 400 µm are attained. CO2 laser is also used for drilling and dicing of the PMMA parts. Considering the thermal properties of PMMA, a novel thermal bonding process with high temperature and low bonding pressure has been developed for assembling PMMA sheets. A high bonding strength of 2.15 MPa is achieved. Subsequent inspection of the cross sections of several microdevices reveals that the dimensions of the channels are well preserved during the bonding process. Electroosmotic mobility of the ablated channel is measured to be 2.47 × 10−4 cm2 V−1 s−1. The functionality of these thermally bonded microfluidic substrates is demonstrated by performing rapid and high-resolution electrophoretic separations of mixture of fluorescein and carboxyfluorescein as well as double-stranded DNA ladders (ΦX174-Hae III dsDNA digest). The performance of the CO2 laser ablated and thermally bonded PMMA devices compares favorably with those fabricated by other professional means.
URI: https://hdl.handle.net/10356/94115
http://hdl.handle.net/10220/7818
DOI: 10.1088/0960-1317/16/8/033
Schools: School of Mechanical and Aerospace Engineering 
Rights: © 2006 IOP Publishing Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of micromechanics and microengineering, IOP Publishing Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/ 10.1088/0960-1317/16/8/033 ].
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MAE Journal Articles

SCOPUSTM   
Citations 5

151
Updated on Mar 15, 2025

Web of ScienceTM
Citations 5

134
Updated on Oct 27, 2023

Page view(s) 5

1,137
Updated on Mar 24, 2025

Download(s) 1

1,866
Updated on Mar 24, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.