Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/94203
Title: Rapid determination of vitamin B12 concentration with a chemiluminescence lab on a chip
Authors: Lok, Khoi Seng
Siti Zubaidah Abdul Muttalib
Lee, Peter Peng Foo
Kwok, Yien Chian
Nguyen, Nam-Trung
Keywords: DRNTU::Engineering::Mechanical engineering
Issue Date: 2012
Source: Lok, K. S., Siti, Z. A. M., Lee, P. P. F., Kwok, Y. C., & Nguyen, N. T. (2012). Rapid Determination of Vitamin B12 Concentration with a Chemiluminescence Lab on a Chip. Lab on a Chip, 12(13), 2353-2361.
Series/Report no.: Lab on a chip
Abstract: This paper reports a novel method for the rapid determination of vitamin B12 concentration in a continuous-flow lab-on-a-chip system. This new method is based on luminol-peroxide chemiluminescence (CL) assays for the detection of cobalt(II) ions in vitamin B12 molecules. The lab-on-a-chip device consisted of two passive micromixers acting as microreactors and a double spiral microchannel network serving as an optical detection region. This system could operate in two modes. In the first mode, samples are acidified and evaluated directly in the microchip. In the second mode, samples are treated externally by acidification prior to detection in the microchip. In the first mode, the linear range obtained was between 1.00 ng ml−1 to 10 μg ml−1, R2 = 0.996, with a relative standard deviation (RSD) of 1.23 to 2.31% (n = 5) and a limit of detection (lod) of 0.368 pg ml−1. The minimum sample volume required and the analytical time were 30 μl and 3.6 s, respectively. In the second mode, the linear range obtained was between 0.10 ng ml−1 to 10 μg ml−1, R2 = 0.994, with the RSD of 0.90 to 2.32% (n = 6) and a lod of 0.576 pg ml−1. The minimum sample and the analytical time required were 50 μl and 6 s, respectively. The lab on a chip working in mode II was successfully used for the determination of vitamin B12 concentrations in nutritional supplemental tablets and hen egg yolks.
URI: https://hdl.handle.net/10356/94203
http://hdl.handle.net/10220/7933
DOI: 10.1039/C2LC00037G
Rights: © 2012 The Royal Society of Chemistry. This is the author created version of a work that has been peer reviewed and accepted for publication by Lab on a Chip, The Royal Society of Chemistry. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: DOI: [http://dx.doi.org/10.1039/C2LC00037G].
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MAE Journal Articles

Files in This Item:
File Description SizeFormat 
LOCManuscriptB12Detectionv5.pdf305.95 kBAdobe PDFThumbnail
View/Open

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.