Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/94660
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLi, Haiwangen
dc.contributor.authorWong, Teck Nengen
dc.contributor.authorNguyen, Nam-Trungen
dc.date.accessioned2012-04-12T03:28:50Zen
dc.date.accessioned2019-12-06T18:59:49Z-
dc.date.available2012-04-12T03:28:50Zen
dc.date.available2019-12-06T18:59:49Z-
dc.date.copyright2010en
dc.date.issued2010en
dc.identifier.citationLi, H., Wong, T. N. & Nguyen, N. T. (2011). A tunable optofluidic lens based on combined effect of hydrodynamics and electroosmosis. Microfluidics and Nanofluidics, 10(5), 1033-1043.en
dc.identifier.urihttps://hdl.handle.net/10356/94660-
dc.description.abstractThis paper presents the modeling and experimental results of a liquid-core liquid-cladding optofluidic lens under the combined effect of hydrodynamics and electroosmosis. To allow the lens to be tuned by a voltage, the cladding fluids are electrically conducting, while the core fluid is non-conducting. Under constant flow rates, mathematical models of two-dimensional dipole flow in a circularly bounded domain and electric field outside the parallel-plate capacitor were used to predict the curvature of the interface. A test device with a circular lens chamber with 2 mm diameter and 250 μm height was fabricated in polymethylmethacrylate (PMMA) using thermal bounding method. Two cladding fluids (aqueous NaCl) and the core fluid (silicone oil) are introduced into the circular domain by syringe pumps. External electric fields are applied on the two cladding fluids. Under the same inlet volumetric flow rates, the applied voltages are varied to tune the curvature of the interfaces between the cladding fluids and the core fluid. The interface shape is measured using fluorescence imaging technique. The results show that the interfaces between the cladding fluids and the core fluid have optically smooth arc shape. Under fixed cladding flow rates, the same voltage forms symmetric biconvex lens only. Different voltages can form biconvex lens, plano-convex lens, and meniscus lens. The experimental results agree well with the presented analytical model.en
dc.language.isoenen
dc.relation.ispartofseriesMicrofluidics and nanofluidicsen
dc.rights© 2012 Springer-Verlag. This is the author created version of a work that has been peer reviewed and accepted for publication by Microfluidics and nanofluidics, Springer-Verlag. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: http://dx.doi.org/10.1007/s10404-010-0732-y.en
dc.subjectDRNTU::Engineering::Mechanical engineeringen
dc.titleA tunable optofluidic lens based on combined effect of hydrodynamics and electroosmosisen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen
dc.identifier.doi10.1007/s10404-010-0732-yen
dc.identifier.rims159432en
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:MAE Journal Articles

SCOPUSTM   
Citations 20

12
Updated on Mar 6, 2021

PublonsTM
Citations 20

11
Updated on Mar 8, 2021

Page view(s) 20

636
Updated on Aug 7, 2022

Download(s) 10

309
Updated on Aug 7, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.