Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/94707
Title: | Self-powering amperometric sensor and biosensor | Authors: | Wong, Lai Peng Wei, Yanyan Toh, Chee-Seng |
Keywords: | DRNTU::Engineering::Chemical engineering::Biochemical engineering | Issue Date: | 2012 | Source: | Wong, L. P., Wei, Y. & Toh, C. S. (2012). Self-powering amperometric sensor and biosensor. Journal of Electroanalytical Chemistry, 671, 80-84. | Series/Report no.: | Journal of electroanalytical chemistry | Abstract: | A unique Prussian blue nanotubes sensor using a two-compartment cell derives the current signal from the chemical energy of the hydrogen peroxide analyte, without input of electrical potentials, is described. The Prussian blue reduces hydrogen peroxide and is itself reduced by electron flow from the counter reaction at the auxiliary electrode. The concentrations of the Prussian blue (PB) and Everitt’s salt (ES) forms of the Prussian blue are maintained at steady-state values, by the hydrogen peroxide reduction and the galvanic cell reaction. This strategy gives low detection limit of 0.1 μM H2O2 with linear range up to 80 μM and is further demonstrated in a model glucose biosensor. The simple design to reduce energy usage opens up the study of amperometricsensor development by selecting anodic and cathodic reactions with suitable thermodynamic potentials with consideration of reactions at the sensing and auxiliary electrodes modified with appropriate mediators or enzymes. | URI: | https://hdl.handle.net/10356/94707 http://hdl.handle.net/10220/8143 |
DOI: | 10.1016/j.jelechem.2012.02.017 | Schools: | School of Physical and Mathematical Sciences | Rights: | © 2012 Elsevier. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of Electroanalytical Chemistry, Elsevier. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/10.1016/j.jelechem.2012.02.017]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | SPMS Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Self-powering amperometric sensor and biosensor.pdf | 5.14 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
20
10
Updated on Mar 20, 2024
Web of ScienceTM
Citations
20
10
Updated on Oct 30, 2023
Page view(s) 5
923
Updated on Mar 27, 2024
Download(s) 5
515
Updated on Mar 27, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.