Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/95621
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLi, Bingen
dc.contributor.authorChua, Grace Hui Yingen
dc.date.accessioned2012-08-15T05:51:32Zen
dc.date.accessioned2019-12-06T19:18:22Z-
dc.date.available2012-08-15T05:51:32Zen
dc.date.available2019-12-06T19:18:22Z-
dc.date.copyright2009en
dc.date.issued2009en
dc.identifier.citationLi, B., & Chua, G. H. Y. (2009). Seismic performance of strengthened reinforced concrete beam-column joints using FRP composites. Journal of structural engineering, 135(10), 1177–1190.en
dc.identifier.urihttps://hdl.handle.net/10356/95621-
dc.description.abstractThree nonseismically detailed interior reinforced concrete beam-column joints, namely, one eccentric and two concentric joints, strengthened with proposed fiber-reinforced polymer FRP wrapping configurations using glass fiber-reinforced polymer and carbon fiber-reinforced polymer strips and sheets, were tested under constant axial compression load and reversed cyclic loading which simulated low to moderate earthquake forces. Seismic performance of the strengthened beam-column joints in terms of their hysteresis response, stiffness, and energy dissipation capacity is evaluated and compared to those of the original and unstrengthened beam-column joints. Results indicate that applying strips at 45º on a flushed eccentric joint core and as cross bracing on the beam and confinement round the column is very effective. All specimens failed with gradual strength deterioration, bond degradation, and debonding of FRP sheets was observed near the joint core. The proposed strengthening schemes were found to be efficient and economical for mass repair or upgrading of nonseismically detailed structures.en
dc.language.isoenen
dc.relation.ispartofseriesJournal of structural engineeringen
dc.rights© 2009 ASCE. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of structural engineering, ASCE. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: http://dx.doi.org/10.1061/(ASCE)0733-9445(2009)135:10(1177).en
dc.subjectDRNTU::Engineeringen
dc.titleSeismic performance of strengthened reinforced concrete beam-column joints using FRP compositesen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Civil and Environmental Engineeringen
dc.identifier.doi10.1061/(ASCE)0733-9445(2009)135:10(1177)en
dc.description.versionAccepted versionen
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:CEE Journal Articles
Files in This Item:
File Description SizeFormat 
187. Seismic Performance of Strengthened Reinforced Concrete Beam.pdf1.24 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 10

36
Updated on Sep 1, 2020

PublonsTM
Citations 10

29
Updated on Mar 5, 2021

Page view(s) 20

512
Updated on Apr 22, 2021

Download(s) 5

634
Updated on Apr 22, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.