Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/96703
Title: Uniform expansion of a polymeric helical stent
Authors: Paryab, Nasim
Cronin, Duane
Lee-Sullivan, Pearl
Ying, Xiong
Boey, Freddy Yin Chiang
Venkatraman, Subbu S.
Keywords: DRNTU::Engineering::Materials
Issue Date: 2012
Source: Paryab, N., Cronin, D., Lee-Sullivan, P., Ying, X., Boey, F. Y. C., & Venkatraman, S. (2012). Uniform expansion of a polymeric helical stent. Journal of medical devices, 6(2), 021012-.
Series/Report no.: Journal of medical devices
Abstract: Helical coil polymeric stents provide an alternative method of stenting compared to traditional metallic stents, but require additional investigation to understand deployment, expansion, and fixation. A bilayer helical coil stent consisting of PLLA and PLGA was investigated using the finite element model to evaluate performance by uniform expansion and subsequent recoiling. In vitro material characterization studies showed that a preinsertion water-soaking step to mimic body implantation conditions provided the required ductility level expansion. In this case, the mechanical contribution of the outer PLGA layer was negligible since it softened significantly under environmental conditions. The viscoelastic response was not considered in this study since the strain rate during expansion was relatively slow and the material response was primarily plastic. The numerical model was validated with available experimental expansion and recoiling data. A parametric study was then undertaken to investigate the effect of stent geometry and coefficient of friction at the stent-cylinder interface on the expansion and recoiling characteristics. The model showed that helical stents exhibit a uniform stress distribution after expansion, which is important for controlled degradation when using biodegradable materials. The results indicated that increasing stent width, pitch value, and coil thickness resulted in a larger diameter after recoiling, which would improve fixation in the artery. It was also noted that a helical stent should have more than five coils to be stable after recoiling. This work is part of a larger research study focused on the performance of a balloon-inflated polymeric helical stent for artery applications.
URI: https://hdl.handle.net/10356/96703
http://hdl.handle.net/10220/17686
ISSN: 1932-6181
DOI: 10.1115/1.4005777
Schools: School of Materials Science & Engineering 
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:MSE Journal Articles

SCOPUSTM   
Citations 20

17
Updated on Nov 30, 2023

Web of ScienceTM
Citations 20

16
Updated on Oct 27, 2023

Page view(s) 20

697
Updated on Dec 7, 2023

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.