Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/97226
Title: Passive infrared camera measurements demonstrate modest effect of mechanically induced internal voids on Dracaena fragrans stem temperature
Authors: Leong, Eng Choon
Fong, Yok-King
Burcham, Daniel C.
Issue Date: 2012
Source: Burcham, D. C., Leong, E.-C., & Fong, Y.-K. (2012). Passive infrared camera measurements demonstrate modest effect of mechanically induced internal voids on Dracaena fragrans stem temperature. Urban Forestry & Urban Greening, 11(2), 169-178.
Series/Report no.: Urban forestry & urban greening
Abstract: The use of infrared cameras as a tree diagnostic device was proposed on the basis that internal defects reduce thermal conductivity and surface temperatures, but existing research has failed to demonstrate a clear connection between these two features. Consequently, two experiments were designed to evaluate the effect of internal voids on stem surface temperature. Cylindrical voids were created in 5 cm diameter stems of Dracaena fragrans by mechanically removing internal tissue. In each experiment, the dimension of internal voids varied among five experimental treatments with two controls. Infrared (IR) images were collected by directly focusing the camera on the stem surfaces concealing internal voids. Infrared images were analyzed using a concurrent mixed methods approach, including qualitative image evaluation and quantitative surface temperature analysis. In each experiment, IR image evaluation revealed a noticeable reduction in surface temperature around the largest void size (3.8 cm). Analyses of linear temperature trending and surface temperature mostly corroborated the visual evaluation. The average temperature above the largest void size was 0.4–0.6 °C lower than other treatments, which remained substantially similar to one another. Overall, these results suggest the technique is exclusively able to identify relatively large internal defects occupying at least 76% of the stem cross-sectional area.
URI: https://hdl.handle.net/10356/97226
http://hdl.handle.net/10220/11757
ISSN: 1618-8667
DOI: 10.1016/j.ufug.2012.01.001
Schools: School of Civil and Environmental Engineering 
Rights: © 2012 Elsevier GmbH.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:CEE Journal Articles

SCOPUSTM   
Citations 20

11
Updated on Apr 27, 2025

Web of ScienceTM
Citations 20

5
Updated on Oct 27, 2023

Page view(s) 20

717
Updated on May 7, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.