Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/97234
Title: Microelectrodes with gold nanoparticles and self-assembled monolayers for in vivo recording of striatal dopamine
Authors: Tsai, Tien-Chun
Guo, Chun Xian
Han, Huan-Zhang
Li, Yu-Ting
Huang, Ying-Zu
Chen, Jason Jia-Jin
Li, Chang Ming
Issue Date: 2012
Source: Tsai, T.-C., Guo, C.-X., Han, H.-Z., Li, Y.-T., Huang, Y.-Z., Li, C. M., et al. (2012). Microelectrodes with gold nanoparticles and self-assembled monolayers for in vivo recording of striatal dopamine. Analyst, 137(12), 2813-2820.
Series/Report no.: Analyst
Abstract: Electrochemical determination of in vivo dopamine (DA) using implantable microelectrodes is essential for monitoring the DA depletion of an animal model of Parkinson's disease (PD), but faces substantial interference from ascorbic acid (AA) in the brain area due to similar electroactive characteristics. This study utilizes gold nanoparticles (Au-NPs) and self-assembled monolayers (SAMs) to modify platinum microelectrodes for improving sensitivity and specificity to DA and alleviating AA interference. With appropriate choice of ω-mercaptoalkane carboxylic acid chain length, our results show that a platinum microelectrode coated with Au-NPs and 3-mercaptopropionic acid (MPA) has approximately an 881-fold specificity to AA. During amperometric measurements, Au-NP/MPA reveals that the responsive current is linearly dependent on DA over the range of 0.01–5 μM with a correlation coefficient of 0.99 and the sensitivity is 2.7-fold that of a conventional Nafion-coated electrode. Other important features observed include fast response time (below 2 s), resistance to albumin adhesion and low detection limit (7 nM) at a signal to noise ratio of 3. Feasibility of in vivo DA recording with the modified microelectrodes is verified by real-time monitoring of electrically stimulated DA release in the striatum of anesthetized rats with various stimulation parameters and administration of a DA uptake inhibitor. The developed microelectrodes present an attractive alternative to the traditional options for continuous electrochemical in vivo DA monitoring.
URI: https://hdl.handle.net/10356/97234
http://hdl.handle.net/10220/10749
ISSN: 0003-2654
DOI: 10.1039/c2an16306c
Rights: © 2012 The Royal Society of Chemistry.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:SCBE Journal Articles

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.