Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/97387
Title: Calibration and limits of camera-based fluorescence correlation spectroscopy : a supported lipid bilayer study
Authors: Bag, Nirmalya
Sankaran, Jagadish
Paul, Alexandra
Kraut, Rachel Susan
Wohland, Thorsten
Keywords: DRNTU::Science::Biological sciences
Issue Date: 2012
Source: Bag, N., Sankaran, J., Paul, A., Kraut, R. S., & Wohland, T. (2012). Calibration and Limits of Camera-Based Fluorescence Correlation Spectroscopy: A Supported Lipid Bilayer Study. ChemPhysChem, 13(11), 2784-2794.
Series/Report no.: ChemPhysChem
Abstract: Camera-based fluorescence correlation spectroscopy (FCS) approaches allow the measurement of thousands of contiguous points yielding excellent statistics and details of sample structure. Imaging total internal reflection FCS (ITIR-FCS) provides these measurements on lipid membranes. Herein, we determine the influence of the point spread function (PSF) of the optical system, the laser power used, and the time resolution of the camera on the accuracy of diffusion coefficient and concentration measurements. We demonstrate that the PSF can be accurately determined by ITIR-FCS and that the laser power and time resolution can be varied over a wide range with limited influence on the measurement of the diffusion coefficient whereas the concentration measurements are sensitive to changes in the measurement parameters. One advantage of ITIR-FCS is that the measurement of the PSF has to be performed only once for a given optical setup, in contrast to confocal FCS in which calibrations have to be performed at least once per measurement day. Using optimized experimental conditions we provide diffusion coefficients for over ten different lipid membranes consisting of one, two and three constituents, measured in over 200000 individual correlation functions. Using software binning and thus the inherent advantage of ITIR-FCS of providing multiple observation areas in a single measurement we test the FCS diffusion law and show how they can be complemented by the local information provided by the difference in cross-correlation functions (ΔCCF). With the determination of the PSF by ITIR-FCS and the optimization of measurement conditions ITIR-FCS becomes a calibration-free method. This allows us to provide measurements of absolute diffusion coefficients for bilayers with different compositions, which were stable over many different bilayer preparations over a time of at least one year, using a single PSF calibration.
URI: https://hdl.handle.net/10356/97387
http://hdl.handle.net/10220/10797
ISSN: 1439-4235
DOI: 10.1002/cphc.201200032
Schools: School of Biological Sciences 
Rights: © 2012 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:SBS Journal Articles

SCOPUSTM   
Citations 10

59
Updated on Mar 23, 2025

Web of ScienceTM
Citations 5

52
Updated on Oct 26, 2023

Page view(s) 5

1,250
Updated on Mar 26, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.