Title: In vivo evaluation of titanium oxide and hydroxyapatite as an artificial cornea skirt
Authors: Beuerman, Roger W.
Mehta, Jodhbir S.
Tan, Xiao Wei
Shi, Zhi Long
Neoh, Koon Gee
Tan, Donald
Khor, Khiam Aik
Keywords: DRNTU::Engineering::Mechanical engineering
Issue Date: 2012
Source: Tan, X. W., Beuerman, R. W., Shi, Z. L., Neoh, K. G., Tan, D., Khor, K. A.,et al. (2012). In vivo evaluation of titanium oxide and hydroxyapatite as an artificial cornea skirt. Journal of materials science : Materials in medicine, 23(4), 1063-1072.
Series/Report no.: Journal of materials science : Materials in medicine
Abstract: Keratoprosthetic devices are subject to chronic inflammatory, pathological processes and the external environment that affect their stability and biocompatibility with the ocular surface and adjacent ocular tissues. We compared the corrosion resistance property and tissue-implant reaction of titanium oxide (TiO2) with hydroxyapatite (HA) in artificial tear fluid and a rabbit skin implantation model. The dissolution properties of the implant surfaces were evaluated with scanning electronic microscope (SEM) and atomic force microscope (AFM). Tissue inflammatory reactions were evaluated by Hematoxylin & Eosin staining, avidin biotin peroxidase complex (ABC) immunoassay and immunofluorescence. SEM and AFM images showed that there was less pitting corrosion on the surface of TiO2 implants compared with HA. TiO2 and HA exhibited a similar pattern of foreign body capsule formation and inflammatory cellular responses. The Collagen I/Collagen III ratio of the TiO2 capsule was higher than that of the HA capsule. TiO2 implants possess a high corrosion resistance property both in vitro and in vivo and the inflammatory cellular response to TiO2 is similar to HA. With regards to corrosion resistance and inflammatory tissue responses, TiO2 appears to be a promising material for keratoprosthetic skirt devices.
URI: https://hdl.handle.net/10356/97698
http://hdl.handle.net/10220/18108
DOI: 10.1007/s10856-012-4578-6
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:MAE Journal Articles

SCOPUSTM   
Citations

21
checked on Sep 4, 2020

WEB OF SCIENCETM
Citations

18
checked on Oct 19, 2020

Page view(s)

526
checked on Oct 25, 2020

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.