Title: | Structural behavior of RC beam-column subassemblages under a middle column removal scenario | Authors: | Yu, Jun Tan, Kang Hai |
Issue Date: | 2013 | Source: | Yu, J., & Tan, K. H. (2013). Structural Behavior of RC Beam-Column Subassemblages under a Middle Column Removal Scenario. Journal of Structural Engineering, 139(2), 233-250. | Series/Report no.: | Journal of structural engineering | Abstract: | Six RC beam-column subassemblages, consisting of two single-bay beams, one middle joint, and two end column stubs, were quasi-statically tested under a middle column removal scenario. The tests were aimed at investigating whether there are alternate load paths that can mitigate progressive collapse. With adequate axial restraints, both compressive arch action (CAA) and catenary action could be mobilized, significantly increasing the structural resistance beyond the beam flexural capacity. The effects of the top and bottom reinforcement ratios at the joint interfaces and beam span-to-depth ratio on structural behavior were studied. The results show that CAA is more beneficial to subassemblages with a short span-to-depth ratio and a low reinforcement ratio, whereas catenary action is more favorable to subassemblages with a large span-to-depth ratio and a high reinforcement ratio, particularly the top reinforcement ratio. As the last defense mechanism to prevent structural collapse, the development of catenary action is highlighted. The onset of catenary action corresponds to the transition of beamaxial force from compression to tension, typically occurring at a central deflection around one beam depth in the tests if no shear failure precedes catenary action.At the catenary action stage, prior to fracture of the bottom bars, structural resistance is contributed by both beam axial tension from longitudinal reinforcement and shear force because of dowel action. If the contribution from rising axial tension exceeds the loss as a result of declining shear force, the structural resistance will still keep on increasing until the fracture of the top bars. Finally, the authors suggest a deformation criterion to determine the catenary action of RC subassemblages; i.e., when the deflection at the middle joint attains 10% of the total beam span length, catenary action capacity is reached. The conservatism of this criterion for design purposes is also discussed. | URI: | https://hdl.handle.net/10356/98138 http://hdl.handle.net/10220/13248 |
DOI: | 10.1061/(ASCE)ST.1943-541X.0000658 | Rights: | © 2013 ASCE. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of structural engineering, ASCE. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI:http://dx.doi.org/10.1061/(ASCE)ST.1943-541X.0000658]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | CEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Structural Behavior of RC Beam-Column Subassemblages under a Middle Column Removal Scenario.pdf | 1.43 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
1
230
Updated on Mar 21, 2023
Web of ScienceTM
Citations
1
180
Updated on Mar 15, 2023
Page view(s) 10
724
Updated on Mar 23, 2023
Download(s) 5
811
Updated on Mar 23, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.