Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/98457
Title: A naked-eye based strategy for semiquantitative immunochromatographic assay
Authors: Zhang, Daohong
Li, Peiwu
Zhang, Wen
Ding, Xiaoxia
Zhang, Qi
Li, Ran
Li, Chang Ming
Issue Date: 2012
Source: Zhang, D., Li, P., Zhang, Q., Li, R., Zhang, W., Ding, X., et al. (2012). A naked-eye based strategy for semiquantitative immunochromatographic assay. Analytica Chimica Acta, 740, 74-79.
Series/Report no.: Analytica chimica acta
Abstract: It is critical to develop a cost-effective quantitative/semiquantitative assay for rapid diagnosis and on-site detection of toxic or harmful substances. Here, a naked-eye based semiquantitative immunochromatographic strip (NSI-strip) was developed, on which three test lines (TLs, TL-I, TL-II and TL-III) were dispensed on a nitrocellulose membrane to form the test zone. Similar as the traditional strip assay for small molecule, the NSI-strip assay was also based on the competitive theory, difference was that the analyte competed three times with the capture reagent for the limited number of antibody binding sites. After the assay, the number of TLs developed in the test zone was inversely proportional to the analyte concentration, thus analyte content levels could be determined by observing the appeared number of TLs. Taking aflatoxin B1 as the model analyte, visual detection limit of the NSI-strip was 0.06 ng mL−1 and threshold concentrations for TL-I–III were 0.125, 0.5, and 2.0 ng mL−1, respectively. Therefore, according to the appeared number of TLs, the following concentration ranges would be detectable by visual examination: 0–0.06 ng mL−1 (negative samples), and 0.06–0.125 ng mL−1, 0.125–0.5 ng mL−1, 0.5–2.0 ng mL−1 and >2.0 ng mL−1 (positive samples). That was to say, compared to traditional strips the NSI-strip could offer more parameter information of the target analyte content. In this way, the NSI-strip improved the qualitative presence/absence detection of traditional strips by measuring the content (range) of target analytes semiquantitatively.
URI: https://hdl.handle.net/10356/98457
http://hdl.handle.net/10220/12413
ISSN: 0003-2670
DOI: 10.1016/j.aca.2012.06.015
Rights: © 2012 Elsevier B.V.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:SCBE Journal Articles

SCOPUSTM   
Citations 50

28
Updated on Feb 27, 2021

PublonsTM
Citations 50

26
Updated on Feb 27, 2021

Page view(s) 10

520
Updated on Mar 5, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.