Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/98964
Title: Continuum heterogeneous biofilm model-A simple and accurate method for effectiveness factor determination
Authors: Gonzo, Elio Emilio.
Wuertz, Stefan.
Rajal, Veronica B.
Issue Date: 2012
Source: Gonzo, E. E., Wuertz, S.,& Rajal, V. B. (2012). Continuum heterogeneous biofilm model-A simple and accurate method for effectiveness factor determination. Biotechnology and Bioengineering, 109(7), 1779-1790.
Series/Report no.: Biotechnology and bioengineering
Abstract: We present a novel analytical approach to describe biofilm processes considering continuum variation of both biofilm density and substrate effective diffusivity. A simple perturbation and matching technique was used to quantify biofilm activity using the steady-state diffusion–reaction equation with continuum variable substrate effective diffusivity and biofilm density, along the coordinate normal to the biofilm surface. The procedure allows prediction of an effectiveness factor, η, defined as the ratio between the observed rate of substrate utilization (reaction rate with diffusion resistance) and the rate of substrate utilization without diffusion limitation. Main assumptions are that (i) the biofilm is a continuum, (ii) substrate is transferred by diffusion only and is consumed only by microorganisms at a rate according to Monod kinetics, (iii) biofilm density and substrate effective diffusivity change in the x direction, (iv) the substrate concentration above the biofilm surface is known, and (v) the substratum is impermeable. With this approach one can evaluate, in a fast and efficient way, the effect of different parameters that characterize a heterogeneous biofilm and the kinetics of the rate of substrate consumption on the behavior of the biological system. Based on a comparison of η profiles the activity of a homogeneous biofilm could be as much as 47.8% higher than that of a heterogeneous biofilm, under the given conditions. A comparison of η values estimated for first order kinetics and η values obtained by numerical techniques showed a maximum deviation of 1.75% in a narrow range of modified Thiele modulus values. When external mass transfer resistance, is also considered, a global effectiveness factor, η0, can be calculated. The main advantage of the approach lies in the analytical expression for the calculation of the intrinsic effectiveness factor η and its implementation in a computer program. For the test cases studied convergence was achieved quickly after four or five iterations. Therefore, the simulation and scale-up of heterogeneous biofilm reactors can be easily carried out.
URI: https://hdl.handle.net/10356/98964
http://hdl.handle.net/10220/12730
ISSN: 0006-3592
DOI: 10.1002/bit.24441
Schools: School of Civil and Environmental Engineering 
School of Biological Sciences 
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:SCELSE Journal Articles

SCOPUSTM   
Citations 20

17
Updated on Mar 22, 2024

Web of ScienceTM
Citations 20

13
Updated on Oct 24, 2023

Page view(s) 50

604
Updated on Mar 28, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.