Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/99628
Title: In vitro effect of a corrosive hostile ocular surface on candidate biomaterials for keratoprosthesis skirt
Authors: Tan, Anna C. S.
Beuerman, Roger W.
Mehta, Jodhbir S.
Tan, Xiao Wei
Riau, Andri
Shi, Zhi Long
Neoh, Koon Gee
Khor, Khiam Aik
Tan, Donald
Keywords: DRNTU::Engineering::Mechanical engineering
Issue Date: 2012
Source: Tan, X. W., Riau, A., Shi, Z. L., Tan, A. C. S., Neoh, K. G., Khor, K. A., Beuerman, R. W., Tan, D., & Mehta, J. S. (2012). In vitro effect of a corrosive hostile ocular surface on candidate biomaterials for keratoprosthesis skirt. British journal of ophthalmology, 96(9), 1252-1258.
Series/Report no.: British journal of ophthalmology
Abstract: Keratoprosthesis (KPro) devices are prone to long-term corrosion and microbiological assault. The authors aimed to compare the inflammatory response and material dissolution properties of two candidate KPro skirt materials, hydroxyapatite (HA) and titania (TiO2) in a simulated in vitro cornea inflammation environment. Lipopolysaccharide-stimulated cytokine secretions were evaluated with human corneal fibroblasts on both HA and TiO2. Material specimens were subjected to electrochemical and long-term incubation test with artificial tear fluid (ATF) of various acidities. Topography and surface roughness of material discs were analysed by scanning electron microscopy and atomic force microscopy. There were less cytokines secreted from human corneal fibroblasts seeded on TiO2 substrates as compared with HA. TiO2 was more resistant to the corrosion effect caused by acidic ATF in contrast to HA. Moreover, the elemental composition of TiO2 was more stable than HA after long-term incubation with ATF. TiO2 is more resistant to inflammatory degradation and has a higher corrosion resistance as compared with HA, and in this regard may be a suitable material to replace HA as an osteo-odonto-keratoprosthesis skirt. This would reduce resorption rates for KPro surgery.
URI: https://hdl.handle.net/10356/99628
http://hdl.handle.net/10220/13735
DOI: 10.1136/bjophthalmol-2012-301633
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:MAE Journal Articles

SCOPUSTM   
Citations

10
checked on Sep 6, 2020

WEB OF SCIENCETM
Citations

7
checked on Oct 23, 2020

Page view(s)

393
checked on Oct 25, 2020

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.