<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T15:19:41Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/11980" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/11980</identifier><datestamp>2026-11-26T20:54:15Z</datestamp><setSpec>com_10356_982</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2152</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en">Phng, Eugene Guan Hwee</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en">Tan Kang Hai</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en" authority="a6dec9ca-977d-49d3-af9e-2924bad6cbb7" confidence="600">School of Civil and Environmental Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned" lang="en">2008-09-25T06:34:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available" lang="en">2008-09-25T06:34:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation" lang="en">Phng, E. G. H. (2006). Fire resistance of steel and composite columns. Master’s thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/11980</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi" lang="en">10.32657/10356/11980</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">A programme of experimental testing has been conducted to investigate the behaviour of steel columns and concrete-encased steel section composite columns at elevated temperature. Heating is attained in an electric furnace. Measurements of internal forces, lateral deflections, axial displacements and temperatures are reported. Twenty steel column specimens were subjected to elevated temperatures. One loading test was carried out at ambient temperature to determine the working load to be applied to the other specimens in the same series for elevated temperature tests. The variable parameters were slenderness ratio and axial restraint ratio. The experimental measurements are presented and compared with predictions from numerical simulations using FEMFAN-3D, a program developed by NTU. It is concluded that buckling temperature decreases as slenderness ratio increases, under a fixed restraint ratio. Applying increased axial restraint to the columns has a negative effect of reducing the buckling temperatures.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en">MASTER OF ENGINEERING (CEE)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en">254 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">DRNTU::Engineering::Civil engineering::Structures and design</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Fire resistance of steel and composite columns</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-26T20:54:13Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-13T00:56:44Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="74ceb1f9-34ee-4542-babb-9a99642baa60">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Fire resistance of steel and composite columns&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/11980&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Phng, Eugene Guan Hwee&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Civil engineering::Structures and design&lt;/Keyword>
   	&lt;Abstract>A programme of experimental testing has been conducted to investigate the behaviour of steel columns and concrete-encased steel section composite columns at elevated temperature. Heating is attained in an electric furnace. Measurements of internal forces, lateral deflections, axial displacements and temperatures are reported. Twenty steel column specimens were subjected to elevated temperatures. One loading test was carried out at ambient temperature to determine the working load to be applied to the other specimens in the same series for elevated temperature tests. The variable parameters were slenderness ratio and axial restraint ratio. The experimental measurements are presented and compared with predictions from numerical simulations using FEMFAN-3D, a program developed by NTU. It is concluded that buckling temperature decreases as slenderness ratio increases, under a fixed restraint ratio. Applying increased axial restraint to the columns has a negative effect of reducing the buckling temperatures.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>