<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-27T09:36:12Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/141010" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/141010</identifier><datestamp>2025-04-30T21:49:53Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Zhang, Xirui</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Cai Wenjian</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="fd1602b1-1a0d-46db-93fa-8a833a7505d9" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail" lang="en_US">ewjcai@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2020-06-03T06:59:01Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2020-06-03T06:59:01Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2020</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/141010</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">With the increasing attention on humidity problem, Dual Cycle Air Dehumidification system（DCADS）is recommended due to its ability to supply a dry, comfortable working and living environment with a lower cost compared with traditional DOAS. DCADS consists of a AHU system as well as a heat pump system which is made up of 4 main components namely compressor, condenser, expansion and evaporator. In order to solve the indoor cooling and dehumidification problem, this project intends to analyse the working principle of this machine, Simulink 3 parts: cooling coil, evaporator and condenser which directly make the heat transfer with input air in DCADS. Suppose the initial input hot wet air is 35℃ with RH 80%, a suitable set of mass rates of refrigerants is also proposed to be determined during the experiment so as to provide a dry, cool fresh air (aimed to at the state of 15℃/51%) at the outlet.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Signal Processing)</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Engineering::Electrical and electronic engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Modelling and simulation of dual cycle air dehumidification system</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8c01880d-c493-49fc-9c82-57150aa68427">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Modelling and simulation of dual cycle air dehumidification system&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2020&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Zhang, Xirui&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering::Electrical and electronic engineering&lt;/Keyword>
   	&lt;Abstract>With the increasing attention on humidity problem, Dual Cycle Air Dehumidification system（DCADS）is recommended due to its ability to supply a dry, comfortable working and living environment with a lower cost compared with traditional DOAS. DCADS consists of a AHU system as well as a heat pump system which is made up of 4 main components namely compressor, condenser, expansion and evaporator. In order to solve the indoor cooling and dehumidification problem, this project intends to analyse the working principle of this machine, Simulink 3 parts: cooling coil, evaporator and condenser which directly make the heat transfer with input air in DCADS. Suppose the initial input hot wet air is 35℃ with RH 80%, a suitable set of mass rates of refrigerants is also proposed to be determined during the experiment so as to provide a dry, cool fresh air (aimed to at the state of 15℃/51%) at the outlet.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>