<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T05:51:15Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/19583" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/19583</identifier><datestamp>2025-04-30T22:23:51Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Wang, Hui Sheng.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Choi, San Shing</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="fd1602b1-1a0d-46db-93fa-8a833a7505d9" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-12-14T06:16:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-12-14T06:16:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">1997</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1997</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/10356/19583</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Protecting transmission lines is an important task to safeguard electric power systems. Faults on transmission lines need to be detected, classified and located accurately for speedy clearance and reclosure. In this framework the most important aspects are fast and reliable fault detection and classification. The traditional protection algorithms are based on deterministic computations on a well-defined model of the system to be protected. This results in difficulty in taking system variation into account when the rules vary. They do not have the ability to adapt dynamically to the system operating conditions, and to make correct decisions if the signals are uncertain.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Engineering</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">140 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">NANYANG TECHNOLOGICAL UNIVERSITY</dim:field>
   <dim:field mdschema="dc" element="subject">DRNTU::Engineering::Electrical and electronic engineering::Electric power::Production, transmission and distribution</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Neurofuzzy implementation of digital protection for power transmission systems</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="927b8db9-772b-4ffe-9ea8-f49933378378">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Neurofuzzy implementation of digital protection for power transmission systems&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>1997&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Wang, Hui Sheng.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering::Electric power::Production, transmission and distribution&lt;/Keyword>
   	&lt;Abstract>Protecting transmission lines is an important task to safeguard electric power systems. Faults on transmission lines need to be detected, classified and located accurately for speedy clearance and reclosure. In this framework the most important aspects are fast and reliable fault detection and classification. The traditional protection algorithms are based on deterministic computations on a well-defined model of the system to be protected. This results in difficulty in taking system variation into account when the rules vary. They do not have the ability to adapt dynamically to the system operating conditions, and to make correct decisions if the signals are uncertain.&lt;/Abstract>