<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T18:24:27Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/19729" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/19729</identifier><datestamp>2025-05-14T16:29:29Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Zhang, Jian</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Cao, Long Jian</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-12-14T06:31:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-12-14T06:31:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">1996</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1996</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/19729</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Static electrification due to dielectric liquid flow has been found to be the cause of many field failures in the large forced-oil-cooled power transformers and in compact HVDC substations. The accumulation of static charge in the oil and isolated solid insulating surfaces causes the electric potential to rise in the same fashion as a Van de Graff generator. The potential builds up until either the rate of charge accumulation equals to the rate of charge leakage, or spark discharges occur. Though the problems of flow electrification were well recognized in petroleum industry, the charging mechanism and effect on transformer insulation and operation are still under active investigation.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Engineering</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">121 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering::Electric power</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Static electrification in large power transformers</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="1b49fb3f-3763-4977-a236-bcab13d2ec2e">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Static electrification in large power transformers&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>1996&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Zhang, Jian&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering::Electric power&lt;/Keyword>
   	&lt;Abstract>Static electrification due to dielectric liquid flow has been found to be the cause of many field failures in the large forced-oil-cooled power transformers and in compact HVDC substations. The accumulation of static charge in the oil and isolated solid insulating surfaces causes the electric potential to rise in the same fashion as a Van de Graff generator. The potential builds up until either the rate of charge accumulation equals to the rate of charge leakage, or spark discharges occur. Though the problems of flow electrification were well recognized in petroleum industry, the charging mechanism and effect on transformer insulation and operation are still under active investigation.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>