<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T07:49:04Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/200410" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/200410</identifier><datestamp>2026-11-22T21:28:36Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Yang, Haoxin</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Tang Yi</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">yitang@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-06-28T12:00:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2025-06-28T12:00:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2024</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/200410</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi">10.32657/10356/200410</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Due to the ever-increasing power demands and the desire to reduce carbon footprints,
conventional fossil fuel-based energy generation is gradually being replaced by
distributed generation systems, which are typically composed of renewable energy and
energy storage systems. In distributed systems that support single-phase sources and
loads, a three-phase four-wire (3P4W) grid connection is typically employed. In this
configuration, the 3P4W DC/AC inverter, serving as a bridge between DC and AC, plays
a critical role. First, it determines the energy conversion efficiency between DC and AC.
Additionally, it must be compatible with both grid-connected and standalone operational
modes while maintaining high power quality. Furthermore, as the only interface with
the grid in a LVDC (low-voltage direct current) microgrid, the 3P4W inverter needs to
monitor the grid status, estimate grid impedance, and even transmit grid frequency
information to harness energy from the LVDC microgrid to enhance the grid inertia.
Although considerable research has been conducted on improving the inverter
performance, most of them focus on three-phase three-wire (3P3W) configurations, and
many existing studies still leave room for improvement. Therefore, this thesis aims to
present a comprehensive discussion on the design and application of a 3P4W 20 kW 50
kHz SiC T-type inverter with enhanced performance.
First, the inverter hardware design is discussed. Although using SiC devices offers
significant benefits in terms of system efficiency and power density, they also present
specific challenges, such as transient vds overvoltage issues caused by hard-switching
turn-off. To address these challenges, a symmetrical layout scheme is adopted to form a
T-type bridge-leg. Additionally, ceramic decoupling capacitors are placed to further
reduce the PCB routing inductance. For verifications, the double pulse test (DPT)
demonstrated that the vds spike can be reduced by around 20% at a 40 A hard-switching
turn-off condition. Building on this design, the developed SiC T-type inverter achieves
a power density of 1.8 kW/L and peak efficiencies of 99.22% and 99.11% in rectifier
and inverter modes, respectively.
Based on the developed SiC T-type inverter hardware, it is essential to guarantee the
neutral-point voltage balancing (NPVB). However, conventional 
NPVB methods designed for three-phase three-wire (3P3W) three-level (3L) inverters, such as commonmode
(CM) voltage injection, cannot be directly applied to 3P4W systems due to the
neutral wire, which inevitably brings undesirable CM voltages and CM currents.
Although dipolar modulation techniques have been used for 3P4W 3L inverters to
balance the neutral-point (NP) voltage, these methods compromise power quality and
system efficiency. To address these challenges, we proposed a minimally injective
carrier-based NPVB method for the developed 3P4W SiC T-type inverters, ensuring
voltage balancing in the split capacitors while maintaining high output power quality.
Building on the proposed NPVB control, the closed-loop control schemes for standalone
and grid-connected operational modes are then designed. To damp the inherent LC and
LCL resonant peaks, digital active damping (DAD) schemes are carefully designed.
Specifically, a capacitor-voltage positive-proportional-feedback DAD (CV-PP-DAD)
method is proposed to extend the effective damping region and improve transient
response in the standalone mode. Additionally, a capacitor-voltage negative-derivativefeedback
DAD (CV-NDF-DAD) method is adopted to damp the LCL resonance in the
grid-connected mode. Building on the damped system, the designed proportional
repetitive (PRE) outer-loop controllers can offer significant advantages in both harmonic
compensation and computational efficiency. For verification, the experimental results
evaluated the performance of the designed closed-loop control schemes, where the total
harmonic distortion (THD) levels of load voltages and grid currents remain below 1%
in the standalone mode and grid-connected mode, respectively.
Based on the developed hardware and closed-loop control schemes, we can explore the
potential applications of the developed T-type SiC inverter. The first application is grid
impedance estimation (GIE). Conventional active GIE methods, such as the PQ variation
method, intentionally introduce power disturbances around the system’s steady-state
operating point. However, this can result in undesired reactive power being injected into
the grid, and its accuracy may be affected by phase-locked loop (PLL) phase angle
variations. To address these challenges, we proposed a noninvasive GIE method that
leverages the inherent operating characteristics of the PLL, ensuring accurate estimation
results across diverse conditions. Another potential application arises when the
developed inverter is used in a distributed LVDC microgrid. By transmitting grid
frequency through DC bus voltage variations, the internal units within the LVDC
microgrid can be mobilized and independently configured to enhance grid inertia
without the need for communication.
The overall connection and relationship of the performed research are summarized as:
the hardware design lays the foundation for the control implementation. With the
hardware and NPVB strategy established, the focus shifts to closed-loop control and
active damping design in both standalone and grid-connected operation. Finally, based
on the developed inverter, its two potential applications are introduced.
As the trend of renewable integration continues, new opportunities will emerge in moreelectronics-
based power systems. In this process, the DC/AC inverters will play an
increasingly important role, taking on greater responsibilities and facing more
challenges, which will need to be addressed through further research efforts.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="rights">This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Design and application of a 20 kW 50 kHz three-phase four-wire T-type SiC inverter</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-22T21:28:35Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-13T00:15:23Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="5b7f1117-47a3-453e-b308-badb11ee48c0">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Design and application of a 20 kW 50 kHz three-phase four-wire T-type SiC inverter&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2024&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/200410&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Yang, Haoxin&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Due to the ever-increasing power demands and the desire to reduce carbon footprints,
conventional fossil fuel-based energy generation is gradually being replaced by
distributed generation systems, which are typically composed of renewable energy and
energy storage systems. In distributed systems that support single-phase sources and
loads, a three-phase four-wire (3P4W) grid connection is typically employed. In this
configuration, the 3P4W DC/AC inverter, serving as a bridge between DC and AC, plays
a critical role. First, it determines the energy conversion efficiency between DC and AC.
Additionally, it must be compatible with both grid-connected and standalone operational
modes while maintaining high power quality. Furthermore, as the only interface with
the grid in a LVDC (low-voltage direct current) microgrid, the 3P4W inverter needs to
monitor the grid status, estimate grid impedance, and even transmit grid frequency
information to harness energy from the LVDC microgrid to enhance the grid inertia.
Although considerable research has been conducted on improving the inverter
performance, most of them focus on three-phase three-wire (3P3W) configurations, and
many existing studies still leave room for improvement. Therefore, this thesis aims to
present a comprehensive discussion on the design and application of a 3P4W 20 kW 50
kHz SiC T-type inverter with enhanced performance.
First, the inverter hardware design is discussed. Although using SiC devices offers
significant benefits in terms of system efficiency and power density, they also present
specific challenges, such as transient vds overvoltage issues caused by hard-switching
turn-off. To address these challenges, a symmetrical layout scheme is adopted to form a
T-type bridge-leg. Additionally, ceramic decoupling capacitors are placed to further
reduce the PCB routing inductance. For verifications, the double pulse test (DPT)
demonstrated that the vds spike can be reduced by around 20% at a 40 A hard-switching
turn-off condition. Building on this design, the developed SiC T-type inverter achieves
a power density of 1.8 kW/L and peak efficiencies of 99.22% and 99.11% in rectifier
and inverter modes, respectively.
Based on the developed SiC T-type inverter hardware, it is essential to guarantee the
neutral-point voltage balancing (NPVB). However, conventional 
NPVB methods designed for three-phase three-wire (3P3W) three-level (3L) inverters, such as commonmode
(CM) voltage injection, cannot be directly applied to 3P4W systems due to the
neutral wire, which inevitably brings undesirable CM voltages and CM currents.
Although dipolar modulation techniques have been used for 3P4W 3L inverters to
balance the neutral-point (NP) voltage, these methods compromise power quality and
system efficiency. To address these challenges, we proposed a minimally injective
carrier-based NPVB method for the developed 3P4W SiC T-type inverters, ensuring
voltage balancing in the split capacitors while maintaining high output power quality.
Building on the proposed NPVB control, the closed-loop control schemes for standalone
and grid-connected operational modes are then designed. To damp the inherent LC and
LCL resonant peaks, digital active damping (DAD) schemes are carefully designed.
Specifically, a capacitor-voltage positive-proportional-feedback DAD (CV-PP-DAD)
method is proposed to extend the effective damping region and improve transient
response in the standalone mode. Additionally, a capacitor-voltage negative-derivativefeedback
DAD (CV-NDF-DAD) method is adopted to damp the LCL resonance in the
grid-connected mode. Building on the damped system, the designed proportional
repetitive (PRE) outer-loop controllers can offer significant advantages in both harmonic
compensation and computational efficiency. For verification, the experimental results
evaluated the performance of the designed closed-loop control schemes, where the total
harmonic distortion (THD) levels of load voltages and grid currents remain below 1%
in the standalone mode and grid-connected mode, respectively.
Based on the developed hardware and closed-loop control schemes, we can explore the
potential applications of the developed T-type SiC inverter. The first application is grid
impedance estimation (GIE). Conventional active GIE methods, such as the PQ variation
method, intentionally introduce power disturbances around the system’s steady-state
operating point. However, this can result in undesired reactive power being injected into
the grid, and its accuracy may be affected by phase-locked loop (PLL) phase angle
variations. To address these challenges, we proposed a noninvasive GIE method that
leverages the inherent operating characteristics of the PLL, ensuring accurate estimation
results across diverse conditions. Another potential application arises when the
developed inverter is used in a distributed LVDC microgrid. By transmitting grid
frequency through DC bus voltage variations, the internal units within the LVDC
microgrid can be mobilized and independently configured to enhance grid inertia
without the need for communication.
The overall connection and relationship of the performed research are summarized as:
the hardware design lays the foundation for the control implementation. With the
hardware and NPVB strategy established, the focus shifts to closed-loop control and
active damping design in both standalone and grid-connected operation. Finally, based
on the developed inverter, its two potential applications are introduced.
As the trend of renewable integration continues, new opportunities will emerge in moreelectronics-
based power systems. In this process, the DC/AC inverters will play an
increasingly important role, taking on greater responsibilities and facing more
challenges, which will need to be addressed through further research efforts.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>