<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T13:10:59Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/200843" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/200843</identifier><datestamp>2025-07-08T11:38:47Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Zhang, Hengming</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Hen-Wei Huang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">henwei.huang@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-07-08T07:02:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2025-07-08T07:02:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/200843</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Traditional approaches typically rely on high-precision embedded sensors, which,
although effective, often require invasive modifications that complicate mechanical
design and increase system complexity. In this dissertation, a non-invasive acoustic
sensing method is proposed for real-time monitoring of drug delivery devices without
altering their structural integrity.
The proposed framework employs a high-sensitivity MEMS microphone to capture
acoustic signals generated during device operation. Through comprehensive signal
processing techniques, the method effectively extracts informative features associated
with motor and rotor activity. Experimental validation was conducted using multiple
gear motors across a range of operating voltages, and ground-truth comparisons were
established through synchronized slow-motion video recording. The results
demonstrate that the dominant acoustic frequencies strongly correlate with device
actuation conditions, allowing accurate inference of operational states.
Furthermore, simulation experiments involving silicone embedding, which
approximates the mechanical properties of human tissue, confirm that the system
retains high reliability and accuracy under near-realistic subcutaneous conditions,
despite some signal attenuation. Overall, this study highlights the significant
advantages of acoustic monitoring — particularly its non-intrusiveness, low cost, and
robustness — and positions it as a promising alternative to conventional sensor-based
approaches for future biomedical device supervision.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Exploring acoustic sensing as a motor feedback alternative for implantable drug delivery systems</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="6ed4bcb9-990d-4f9d-b9dd-a434ce08286b">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Exploring acoustic sensing as a motor feedback alternative for implantable drug delivery systems&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Zhang, Hengming&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Traditional approaches typically rely on high-precision embedded sensors, which,
although effective, often require invasive modifications that complicate mechanical
design and increase system complexity. In this dissertation, a non-invasive acoustic
sensing method is proposed for real-time monitoring of drug delivery devices without
altering their structural integrity.
The proposed framework employs a high-sensitivity MEMS microphone to capture
acoustic signals generated during device operation. Through comprehensive signal
processing techniques, the method effectively extracts informative features associated
with motor and rotor activity. Experimental validation was conducted using multiple
gear motors across a range of operating voltages, and ground-truth comparisons were
established through synchronized slow-motion video recording. The results
demonstrate that the dominant acoustic frequencies strongly correlate with device
actuation conditions, allowing accurate inference of operational states.
Furthermore, simulation experiments involving silicone embedding, which
approximates the mechanical properties of human tissue, confirm that the system
retains high reliability and accuracy under near-realistic subcutaneous conditions,
despite some signal attenuation. Overall, this study highlights the significant
advantages of acoustic monitoring — particularly its non-intrusiveness, low cost, and
robustness — and positions it as a promising alternative to conventional sensor-based
approaches for future biomedical device supervision.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>