<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T16:27:58Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/202031" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/202031</identifier><datestamp>2026-11-28T22:01:12Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Luo, Lingfeng</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Amer M. Y. M. Ghias</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="research" authority="28cd318a-071a-4460-a5ed-48d476897792" confidence="600">Clean Energy Research Laboratory (CERL)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">amer.ghias@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-09-11T00:24:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2025-09-11T00:24:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/202031</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi">10.32657/10356/202031</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">This research focuses on the assessment and maintenance of power assets, particularly power transformers, which are vital to the gird. The research is conducted in three stages. Firstly, a cumulative modified model was developed that incorporates monitoring condition data, such as ambient temperature, humidity, and partial discharge, into the transformer aging model, improving failure prediction accuracy. On the second stage, the research establishes a composite Health Index model that combines monitoring condition data and historical failure statistics, adapting quantile mapping method to integrate data from these two different dimensions into a composite model, which provides a long-term and comprehensive health condition assessment for transformers. Lastly, a risk-based optimization method for maintenance scheduling is proposed. This method considers the maintenance effects on transformer failure risk and minimizes the total risk for long-term operation by balancing failure risk and maintenance cost.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="rights">This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Power asset health condition assessment and corresponding maintenance</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2025-09-10T09:13:19.452Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-28T22:01:11Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="95965620-6d24-4475-9678-0efe284c07fc">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Power asset health condition assessment and corresponding maintenance&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/202031&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Luo, Lingfeng&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>This research focuses on the assessment and maintenance of power assets, particularly power transformers, which are vital to the gird. The research is conducted in three stages. Firstly, a cumulative modified model was developed that incorporates monitoring condition data, such as ambient temperature, humidity, and partial discharge, into the transformer aging model, improving failure prediction accuracy. On the second stage, the research establishes a composite Health Index model that combines monitoring condition data and historical failure statistics, adapting quantile mapping method to integrate data from these two different dimensions into a composite model, which provides a long-term and comprehensive health condition assessment for transformers. Lastly, a risk-based optimization method for maintenance scheduling is proposed. This method considers the maintenance effects on transformer failure risk and minimizes the total risk for long-term operation by balancing failure risk and maintenance cost.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>