<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T10:06:46Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/202249" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/202249</identifier><datestamp>2026-11-26T21:37:10Z</datestamp><setSpec>com_10356_986</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2218</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Wong, Mark Kei Fong</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Ng Yin Kwee</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="50c1ae5d-dbc2-4261-8647-8a6bc78fd13d" confidence="500">School of Mechanical and Aerospace Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">mykng@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-10-02T23:17:40Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2025-10-02T23:17:40Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/202249</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi">10.32657/10356/202249</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Background: Cardiovascular and metabolic diseases such as diabetes are on the rise. These two diseases are comorbid and referred to as an umbrella term cardiometabolic diseases (CMD). A major problem with therapeutic posology of CMDs is the reliance on reliable clinical monitoring to inform physicians about the efficacy of prescription medication. 
Justification: Existing blood pressure monitors interfere with lifestyle habits and blood glucose monitors require invasive daily blood sampling, leading to poor compliance, suboptimal adherence to treatment regimens and secondary complications. In addition, chronic disease monitoring generates an almost unmanageable amount and complexity of time-based data that is challenging for healthcare professionals to manage and organize. There is a profound need for a new generation of portable monitoring methods.
Findings: This research study has successfully achieved predictive assessment of blood pressure (BP) and blood glucose level (BGL) in a non-invasive and unobtrusive manner, while improving an AI/ML prediction system as a diagnostic, predictive clinical tool for long-term chronic monitoring of CMD. This work also avoids reliance on exotic metamaterials or expensive benchtop equipment that prevent potential future commercial application to reduce future barriers to translational research. The research also addressed the problem of large data set dependency in modern machine learning (ML) models by implementing a spatio-temporal morphological analysis approach that integrates the nonlinear hemorheological mechanisms of the vascular system. 
Key Results: This research successfully developed improved generations of time-differentiated dual-point photoplethysmograms (2PPG) as a non-invasive bio-optical sensor modality and recorded pulsatile blood flow in subjects non-invasively and non-exclusively in over 114 distinct individuals. Inter- and intra-subject estimates of blood pressure and blood glucose based on hemorheologically constrained physics informed neural networks (4D-PINN) achieving an estimation accuracy of r = 0.973 to r=0.984 over the entire blood pressure range with a mean averaged error (MAE) of 1.72 ±1.65 mmHg and an R² value of 0.9884. The model also works well for blood glucose estimates with a root mean square error (RMSE) of 18.31 mg/dL and MAE of 14.58mg/dL, even in subjects taking medication. 
The study also proposes a new method for visualizing and compressing data and is now a patented method (WO2024205510) called “Plethysmorphometry&amp;quot; (PMM), which shows a lossless compression ratio (CR) of better than 4.3 when PPG data is stored for longer than 3 minutes and up to 1 hours in this study suggesting suitable viability for long-term data storage. 
Conclusion and Significance: The proposed system does not require radial/brachial occlusion or blood sampling on the finger and is therefore inconspicuous for normal lifestyle. It can be implemented using standard microelectronic manufacturing techniques and toolchains and PPG measurements of only 15 heart beats are required, a comparable measurement duration to brachial oscillometric blood pressure measurement. 
The results of the study could revolutionize the way long-term cardiovascular monitoring can be visualized in ambulatory patients to monitor/track adherence to therapy and as a potential tool to improve the efficacy of clinical interventions or inform treatment posology.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="relation">Singapore Health Technologies Consortium (HealthTEC.SG) (Grant Award 020442-00001)</dim:field>
   <dim:field mdschema="dc" element="rights">This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0).</dim:field>
   <dim:field mdschema="dc" element="subject">Medicine, Health and Life Sciences</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Cardiometabolic</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Photoplethysmography</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Machine learning</dim:field>
   <dim:field mdschema="dc" element="title">Deep analytics from advanced wearable photoplethysmographic signals for cardiovascular and metabolic disease diagnostics</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2025-10-02T17:03:37.417Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-26T21:37:09Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="a3867a2d-4d03-4fdc-aaf5-f59be67b04f4">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Deep analytics from advanced wearable photoplethysmographic signals for cardiovascular and metabolic disease diagnostics&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/202249&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Wong, Mark Kei Fong&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Medicine, Health and Life Sciences&lt;/Keyword>
   	&lt;Abstract>Background: Cardiovascular and metabolic diseases such as diabetes are on the rise. These two diseases are comorbid and referred to as an umbrella term cardiometabolic diseases (CMD). A major problem with therapeutic posology of CMDs is the reliance on reliable clinical monitoring to inform physicians about the efficacy of prescription medication. 
Justification: Existing blood pressure monitors interfere with lifestyle habits and blood glucose monitors require invasive daily blood sampling, leading to poor compliance, suboptimal adherence to treatment regimens and secondary complications. In addition, chronic disease monitoring generates an almost unmanageable amount and complexity of time-based data that is challenging for healthcare professionals to manage and organize. There is a profound need for a new generation of portable monitoring methods.
Findings: This research study has successfully achieved predictive assessment of blood pressure (BP) and blood glucose level (BGL) in a non-invasive and unobtrusive manner, while improving an AI/ML prediction system as a diagnostic, predictive clinical tool for long-term chronic monitoring of CMD. This work also avoids reliance on exotic metamaterials or expensive benchtop equipment that prevent potential future commercial application to reduce future barriers to translational research. The research also addressed the problem of large data set dependency in modern machine learning (ML) models by implementing a spatio-temporal morphological analysis approach that integrates the nonlinear hemorheological mechanisms of the vascular system. 
Key Results: This research successfully developed improved generations of time-differentiated dual-point photoplethysmograms (2PPG) as a non-invasive bio-optical sensor modality and recorded pulsatile blood flow in subjects non-invasively and non-exclusively in over 114 distinct individuals. Inter- and intra-subject estimates of blood pressure and blood glucose based on hemorheologically constrained physics informed neural networks (4D-PINN) achieving an estimation accuracy of r = 0.973 to r=0.984 over the entire blood pressure range with a mean averaged error (MAE) of 1.72 ±1.65 mmHg and an R² value of 0.9884. The model also works well for blood glucose estimates with a root mean square error (RMSE) of 18.31 mg/dL and MAE of 14.58mg/dL, even in subjects taking medication. 
The study also proposes a new method for visualizing and compressing data and is now a patented method (WO2024205510) called “Plethysmorphometry&amp;quot; (PMM), which shows a lossless compression ratio (CR) of better than 4.3 when PPG data is stored for longer than 3 minutes and up to 1 hours in this study suggesting suitable viability for long-term data storage. 
Conclusion and Significance: The proposed system does not require radial/brachial occlusion or blood sampling on the finger and is therefore inconspicuous for normal lifestyle. It can be implemented using standard microelectronic manufacturing techniques and toolchains and PPG measurements of only 15 heart beats are required, a comparable measurement duration to brachial oscillometric blood pressure measurement. 
The results of the study could revolutionize the way long-term cardiovascular monitoring can be visualized in ambulatory patients to monitor/track adherence to therapy and as a potential tool to improve the efficacy of clinical interventions or inform treatment posology.&lt;/Abstract>