<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T03:14:22Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/20394" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/20394</identifier><datestamp>2025-05-14T20:42:07Z</datestamp><setSpec>com_10356_2326</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2328</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Serban, Adrian.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Lee, Sing</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="e2952dc9-1a9e-4528-bde7-520f27d0ba7d" confidence="600">National Institute of Education</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-12-14T09:40:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-12-14T09:40:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">1995</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">1995</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/20394</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">An analysis of data for plasma focus devices in their wide range of sizes has been made. The data show that for neutron optimized operation all plasma focus devices have the same peak axial sheath velocity of 10 cm/us or a little less, driven by a standard value of characteristic current per unit anode radius I/a of 250 kA/cm.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Doctor of Philosophy</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">270 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">NANYANG TECHNOLOGICAL UNIVERSITY</dim:field>
   <dim:field mdschema="dc" element="subject">DRNTU::Science::Physics::Electricity and magnetism</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Anode geometry and focus characteristics</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="68407e73-6525-483d-a4a2-88e4c79b84ca">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Anode geometry and focus characteristics&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>1995&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Serban, Adrian.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Science::Physics::Electricity and magnetism&lt;/Keyword>
   	&lt;Abstract>An analysis of data for plasma focus devices in their wide range of sizes has been made. The data show that for neutron optimized operation all plasma focus devices have the same peak axial sheath velocity of 10 cm/us or a little less, driven by a standard value of characteristic current per unit anode radius I/a of 250 kA/cm.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>