<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T21:34:42Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/205176" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/205176</identifier><datestamp>2025-12-20T11:55:17Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Liny, Zhuangkai</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Xu Yan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">xuyan@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-12-19T12:37:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2025-12-19T12:37:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/205176</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Fast and reliable diagnosis of inverter open-circuit faults is vital to power quality and 
system security in inverter-dominated microgrids. This work develops a unified 
evaluation pipeline and a curated dataset across four distributed generators, 
aggregating frequency (F), voltage (V), active-power (P), and reactive-power (Q) 
signals. The corpus spans 28 operating states with 8,400 labeled records. Features are 
standardized using training statistics and evaluated under a stratified 70/30 split across 
all fifteen non-empty F/V/P/Q combinations. Five representative classifiers—k
Nearest Neighbors, linear Support Vector Machine, Random Forest, single Decision 
Tree, and PCA-regularized Linear Discriminant Analysis—are compared with two 
metrics: overall accuracy and fault-only accuracy. Results indicate stable overall 
accuracy in the mid-80% range, with frequency-centric feature sets being the most 
reliable; fault-only accuracy is slightly lower, reflecting the added difficulty among 
fault subclasses. Lightweight learners remain competitive under a consistent 
preprocessing routine, while naive multi-variable fusion yields diminishing returns 
due to correlation and redundancy. The study contributes a fair-comparison protocol, 
comprehensive ablations over variable sets, and practical guidance on robustness, 
computational cost, interpretability, and engineering implementation, offering 
reproducible baselines and actionable insights for intelligent protection in inverter
dominated microgrids.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Learning-based fault detection of inverter-based resources in microgrids</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2025-12-19T09:25:47.008Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="e427214a-116f-490f-ae98-33f567d99976">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Learning-based fault detection of inverter-based resources in microgrids&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Liny, Zhuangkai&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Fast and reliable diagnosis of inverter open-circuit faults is vital to power quality and 
system security in inverter-dominated microgrids. This work develops a unified 
evaluation pipeline and a curated dataset across four distributed generators, 
aggregating frequency (F), voltage (V), active-power (P), and reactive-power (Q) 
signals. The corpus spans 28 operating states with 8,400 labeled records. Features are 
standardized using training statistics and evaluated under a stratified 70/30 split across 
all fifteen non-empty F/V/P/Q combinations. Five representative classifiers—k
Nearest Neighbors, linear Support Vector Machine, Random Forest, single Decision 
Tree, and PCA-regularized Linear Discriminant Analysis—are compared with two 
metrics: overall accuracy and fault-only accuracy. Results indicate stable overall 
accuracy in the mid-80% range, with frequency-centric feature sets being the most 
reliable; fault-only accuracy is slightly lower, reflecting the added difficulty among 
fault subclasses. Lightweight learners remain competitive under a consistent 
preprocessing routine, while naive multi-variable fusion yields diminishing returns 
due to correlation and redundancy. The study contributes a fair-comparison protocol, 
comprehensive ablations over variable sets, and practical guidance on robustness, 
computational cost, interpretability, and engineering implementation, offering 
reproducible baselines and actionable insights for intelligent protection in inverter
dominated microgrids.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>