<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T07:30:52Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/205255" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/205255</identifier><datestamp>2025-12-30T11:32:36Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Josia, Handrata Roy</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">See Kye Yak</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="research" authority="ed2a151e-2488-4dc2-aa00-9eac303098d1" confidence="600">Electromagnetic Effects Research Laboratory</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">EKYSEE@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-12-29T11:12:35Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2025-12-29T11:12:35Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/205255</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Partial discharges (PD) are a key failure component in high voltage insulation, typically emerging from locally increased electric fields around voids and impurities. For the case of PD phenomenon, they were modelled and simulated using the Finite Integration Technique (FIT) implemented in CST Simulia in order to compare electric fields as well as Partial Discharge Inception Voltages (PDIVs) and discharge characteristics with several electrode gap distances. The electric field was sampled at 0.05 ns time frame and multiple simulations were performed to compute the PDIV values. It was proved that larger air gaps needed higher PDIVs because of the longer ionization path, while higher applied voltages lead to stronger discharges with increased peak currents, integrated charges, and radiated energy. To capture these radiated signals, a monopole antenna resonating near 1.07 GHz was designed and simulated. The antenna analysis and an evaluation of S11 and far-field showed that it was suitable for the detection of short-period signals emitted during high-frequency PD events. The results reveal a clear correlation between gap distance, applied voltage and PD severity, as well as validating the potential of UHF antenna-based methods for detecting PD. The proposed combined methodology could enhance the diagnosis of insulation systems and offer a mean to develop more reliable condition assessment methods for high voltage equipment.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="relation">ISM-DISS-05409</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Partial discharge modelling</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Finite integration technique</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Electric field</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">PDIV</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">UHF antenna</dim:field>
   <dim:field mdschema="dc" element="title">Numerical modelling of partial discharge in high-voltage systems</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2025-12-29T06:24:50.672Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="62f87b75-9990-4f30-93c3-e5de7c4bc003">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Numerical modelling of partial discharge in high-voltage systems&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Josia, Handrata Roy&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Partial discharges (PD) are a key failure component in high voltage insulation, typically emerging from locally increased electric fields around voids and impurities. For the case of PD phenomenon, they were modelled and simulated using the Finite Integration Technique (FIT) implemented in CST Simulia in order to compare electric fields as well as Partial Discharge Inception Voltages (PDIVs) and discharge characteristics with several electrode gap distances. The electric field was sampled at 0.05 ns time frame and multiple simulations were performed to compute the PDIV values. It was proved that larger air gaps needed higher PDIVs because of the longer ionization path, while higher applied voltages lead to stronger discharges with increased peak currents, integrated charges, and radiated energy. To capture these radiated signals, a monopole antenna resonating near 1.07 GHz was designed and simulated. The antenna analysis and an evaluation of S11 and far-field showed that it was suitable for the detection of short-period signals emitted during high-frequency PD events. The results reveal a clear correlation between gap distance, applied voltage and PD severity, as well as validating the potential of UHF antenna-based methods for detecting PD. The proposed combined methodology could enhance the diagnosis of insulation systems and offer a mean to develop more reliable condition assessment methods for high voltage equipment.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>