<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T00:23:03Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/205337" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/205337</identifier><datestamp>2026-01-07T11:17:43Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Chen, Yufei</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Mohammed Yakoob Siyal</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">EYAKOOB@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-01-07T04:31:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-01-07T04:31:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/205337</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">The quality of medical images is easily affected by various types of noise, which can affect accurate diagnosis and subsequent analysis. To systematically evaluate the validity of noise-reducing methods, this study focuses on two general modalities: Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). 
The physical origins of noise in these modalities are first analyzed. Controllable simulations on clean images are conducted to generate a benchmark dataset. A range of denoising algorithms, from image processing-based traditional filters to state-of-the-art deep learning models, is then applied. 
Their performance is assessed through quantitative metrics like Peak Signal to Noise Ratio (PSNR) and Structural Similarity Index (SSIM). Furthermore, we directly evaluate the clinical utility of denoising by measuring its impact on the accuracy of a downstream segmentation task. 
Results demonstrate that deep learning-based methods outperform other methods in restoring image quality and in enhancing segmentation precision. The Transformer-based Restormer has the best performance.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Medical Image Processing</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Deep Learning</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Image Denoising</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Magnetic Resonance Imaging (MRI)</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Computed Tomography (CT)</dim:field>
   <dim:field mdschema="dc" element="title">Machine learning and image processing algorithms for advanced medical image applications</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-01-06T07:44:21.458Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="2399f772-1ca9-4de1-af77-ad92844c797e">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Machine learning and image processing algorithms for advanced medical image applications&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Chen, Yufei&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>The quality of medical images is easily affected by various types of noise, which can affect accurate diagnosis and subsequent analysis. To systematically evaluate the validity of noise-reducing methods, this study focuses on two general modalities: Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). 
The physical origins of noise in these modalities are first analyzed. Controllable simulations on clean images are conducted to generate a benchmark dataset. A range of denoising algorithms, from image processing-based traditional filters to state-of-the-art deep learning models, is then applied. 
Their performance is assessed through quantitative metrics like Peak Signal to Noise Ratio (PSNR) and Structural Similarity Index (SSIM). Furthermore, we directly evaluate the clinical utility of denoising by measuring its impact on the accuracy of a downstream segmentation task. 
Results demonstrate that deep learning-based methods outperform other methods in restoring image quality and in enhancing segmentation precision. The Transformer-based Restormer has the best performance.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>