<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T08:13:06Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/205697" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/205697</identifier><datestamp>2026-02-04T11:41:10Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Liu, Yiyang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Tang Yi</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">yitang@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-02-04T01:30:33Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-02-04T01:30:33Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/205697</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">To address the efficiency limitations of conventional Dual Active Bridge (DAB) converters in high-power applications, this report presents the design of a 10kW, 800V/500V bidirectional CLLLC resonant converter tailored for Level-3 DC fast charging and Vehicle-to-Grid (V2G) scenarios. A mathematical model is established based on the Fundamental Harmonic Approximation (FHA). An optimized parameter design method is proposed, selecting an inductance ratio and a quality factor to guarantee full-range soft-switching while minimizing conduction losses. A dual-closed-loop Single Phase Shift (SPS) control strategy is implemented with empirically tuned PI parameters. Simulation results on the PLECS platform verify stable operation at the rated 10kW power. Zero Voltage Switching (ZVS) for the primary side and Zero Current Switching (ZCS) for the secondary side are achieved in both forward and reverse power flow modes, and the system demonstrates excellent dynamic performance during load steps and power reversals.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Bidirectional DC/DC Converter</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">CLLLC Resonant Converter</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Zero Voltage Switching</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Dual-loop Control</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Parameter Optimization</dim:field>
   <dim:field mdschema="dc" element="title">Design of a CLLLC resonant tank for dual-active-bridge converters</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-02-03T09:20:34.441Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="89c0e208-39b5-42d8-8947-524f3e61f8b5">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Design of a CLLLC resonant tank for dual-active-bridge converters&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Liu, Yiyang&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>To address the efficiency limitations of conventional Dual Active Bridge (DAB) converters in high-power applications, this report presents the design of a 10kW, 800V/500V bidirectional CLLLC resonant converter tailored for Level-3 DC fast charging and Vehicle-to-Grid (V2G) scenarios. A mathematical model is established based on the Fundamental Harmonic Approximation (FHA). An optimized parameter design method is proposed, selecting an inductance ratio and a quality factor to guarantee full-range soft-switching while minimizing conduction losses. A dual-closed-loop Single Phase Shift (SPS) control strategy is implemented with empirically tuned PI parameters. Simulation results on the PLECS platform verify stable operation at the rated 10kW power. Zero Voltage Switching (ZVS) for the primary side and Zero Current Switching (ZCS) for the secondary side are achieved in both forward and reverse power flow modes, and the system demonstrates excellent dynamic performance during load steps and power reversals.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>