<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T08:34:49Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/20673" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/20673</identifier><datestamp>2025-05-14T18:32:46Z</datestamp><setSpec>com_10356_986</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2218</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Ubong Udo Solomon</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Gong Haiqing, Thomas</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="50c1ae5d-dbc2-4261-8647-8a6bc78fd13d" confidence="600">School of Mechanical and Aerospace Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2009-12-22T07:14:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2009-12-22T07:14:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2008</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2008</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/20673</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Enrichment of a desired population of cell from a pool of multispecies sample by cell&#xd;
sorting is an indispensable step in many cell-based studies. The current method utilizes expensive cell sorting instruments, which are based on flow cytometry methods and&#xd;
requires a comparatively large amount of reagents and samples. This work takes&#xd;
advantage of MEMS technology in developing and optimizing a low-cost passive&#xd;
microdevice, which analyses with reduced reagent volume at reduced analysis time.&#xd;
Different biochip designs were fabricated to study the effects of pumping mechanism,&#xd;
channel coating, and channel geometry on the efficiency of cell sorting on chip.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Mechanics &amp; Processing of Materials)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">122 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Mechanical engineering</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Microfluidic control in a biochip for DNA analysis</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="4308d55a-4352-4dcd-9556-fba32c553e21">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Microfluidic control in a biochip for DNA analysis&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2008&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Ubong Udo Solomon&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Mechanical engineering&lt;/Keyword>
   	&lt;Abstract>Enrichment of a desired population of cell from a pool of multispecies sample by cell&#xd;
sorting is an indispensable step in many cell-based studies. The current method utilizes expensive cell sorting instruments, which are based on flow cytometry methods and&#xd;
requires a comparatively large amount of reagents and samples. This work takes&#xd;
advantage of MEMS technology in developing and optimizing a low-cost passive&#xd;
microdevice, which analyses with reduced reagent volume at reduced analysis time.&#xd;
Different biochip designs were fabricated to study the effects of pumping mechanism,&#xd;
channel coating, and channel geometry on the efficiency of cell sorting on chip.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>