<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T14:27:29Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/210423" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/210423</identifier><datestamp>2026-03-01T11:21:15Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Yao, Hengji</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Jiang Xudong</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">EXDJiang@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-02-28T11:34:58Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-02-28T11:34:58Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/210423</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Screening mammography provides four complementary views per examination, yet most medical vision–language model (VLM) studies remain limited to single- view settings. This dissertation presents a unified framework for multi-view breast cancer risk classification on a subset of the CSAW-CC cohort, integrat- ing early-fusion and late-fusion strategies with zero-shot, prompt-ensemble, and few-shot VLM adaptation. Three fusion strategies—clinical-order early fusion (COEF), a proposed centre-biased early fusion (CBEF), and feature-level late fu- sion (FLF)—are systematically evaluated using BiomedCLIP, BiomedCoOp, and a fully supervised ViT baseline. Experiments demonstrate that multi-view input substantially boosts performance: the supervised ViT achieves the highest accu- racy at 57.01% under CBEF, outperforming COEF (56.89%) and FLF (56.77%). For VLMs, prompt ensemble markedly improves BiomedCLIP from 29.45% to 56.65% under CBEF, matching the supervised model despite requiring no addi- tional training. BiomedCoOp achieves 50.29% (16-shot) under CBEF, improving over zero-shot VLMs but still below the supervised ViT due to domain shift and the subtle nature of risk-related imaging cues. Overall, this work establishes a controlled multi-view benchmark for VLMs in mammography, introduces an anatomically informed fusion design, and clarifies the conditions under which VLM-based few-shot learning is competitive with full supervision.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="relation">ISM-DISS-05421</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Vision language model</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Mammography</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Prompt learning</dim:field>
   <dim:field mdschema="dc" element="title">Multi-view mammography classification via vision-language prompt learning</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-02-27T11:00:09.297Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="4f1cd75d-7b4c-4703-84a1-eac39baecd52">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Multi-view mammography classification via vision-language prompt learning&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Yao, Hengji&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Screening mammography provides four complementary views per examination, yet most medical vision–language model (VLM) studies remain limited to single- view settings. This dissertation presents a unified framework for multi-view breast cancer risk classification on a subset of the CSAW-CC cohort, integrat- ing early-fusion and late-fusion strategies with zero-shot, prompt-ensemble, and few-shot VLM adaptation. Three fusion strategies—clinical-order early fusion (COEF), a proposed centre-biased early fusion (CBEF), and feature-level late fu- sion (FLF)—are systematically evaluated using BiomedCLIP, BiomedCoOp, and a fully supervised ViT baseline. Experiments demonstrate that multi-view input substantially boosts performance: the supervised ViT achieves the highest accu- racy at 57.01% under CBEF, outperforming COEF (56.89%) and FLF (56.77%). For VLMs, prompt ensemble markedly improves BiomedCLIP from 29.45% to 56.65% under CBEF, matching the supervised model despite requiring no addi- tional training. BiomedCoOp achieves 50.29% (16-shot) under CBEF, improving over zero-shot VLMs but still below the supervised ViT due to domain shift and the subtle nature of risk-related imaging cues. Overall, this work establishes a controlled multi-view benchmark for VLMs in mammography, introduces an anatomically informed fusion design, and clarifies the conditions under which VLM-based few-shot learning is competitive with full supervision.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>