<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T05:51:14Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/210645" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/210645</identifier><datestamp>2026-03-19T11:12:38Z</datestamp><setSpec>com_10356_986</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2218</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Zhu, Danfeng</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Chen I-Ming</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="50c1ae5d-dbc2-4261-8647-8a6bc78fd13d" confidence="500">School of Mechanical and Aerospace Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">MICHEN@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-03-19T06:50:05Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-03-19T06:50:05Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/210645</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">With the increasing potential of humanoid robots in medical applications, their deployment in the post-processing scenarios of Central Sterile Supply Departments (CSSD) remains a significant challenge. Currently, for flat, high-aspect-ratio surgical instruments such as scalpel handles and hemostats, existing general-purpose dexterous hands or traditional grippers struggle to achieve both grasping stability and adaptability. To address this problem, this thesis proposes a specialized gripper design based on the Energy-Bounded Partial Caging theory and validates its design feasibility in a simulation environment. Targeting the additional roll failure mode, a proprioception-based variable impedance control strategy is further proposed to compensate for this limitation. Experimental results indicate that the system achieves a grasping success rate exceeding 95%when sorting typical instruments like scalpel handles and hemostats. Comparative experiments further reveal that, in the presence of initial pose deviations, the proposed system exhibits superior compliance and robustness compared to high-stiffness position control. This study provides a significant theoretical foundation and engineering solution for the robotic manipulation of flat objects in unstructured medical environments.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Humanoid Robot</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">CSSD</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Surgical Instrument Sorting</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Energy-Bounded Partial Caging</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Variable Impedance Control</dim:field>
   <dim:field mdschema="dc" element="title">Design and performance optimization of a robotic end-effector for unitree G1 in surgical instrument reprocessing</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-03-19T04:43:19.787Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="1c9ed78d-e497-4a61-82d7-38e79f038c5d">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Design and performance optimization of a robotic end-effector for unitree G1 in surgical instrument reprocessing&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Zhu, Danfeng&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>With the increasing potential of humanoid robots in medical applications, their deployment in the post-processing scenarios of Central Sterile Supply Departments (CSSD) remains a significant challenge. Currently, for flat, high-aspect-ratio surgical instruments such as scalpel handles and hemostats, existing general-purpose dexterous hands or traditional grippers struggle to achieve both grasping stability and adaptability. To address this problem, this thesis proposes a specialized gripper design based on the Energy-Bounded Partial Caging theory and validates its design feasibility in a simulation environment. Targeting the additional roll failure mode, a proprioception-based variable impedance control strategy is further proposed to compensate for this limitation. Experimental results indicate that the system achieves a grasping success rate exceeding 95%when sorting typical instruments like scalpel handles and hemostats. Comparative experiments further reveal that, in the presence of initial pose deviations, the proposed system exhibits superior compliance and robustness compared to high-stiffness position control. This study provides a significant theoretical foundation and engineering solution for the robotic manipulation of flat objects in unstructured medical environments.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>