<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T16:21:55Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/212751" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/212751</identifier><datestamp>2026-04-08T11:38:34Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Cao, Shuwen</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Hen-Wei Huang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">henwei.huang@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-04-07T23:52:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-04-07T23:52:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/212751</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Phonocardiogram (PCG) analysis provides a non-invasive and low-cost technical means for cardiovascular disease screening, but it is often limited by noise interference and high non-stationarity and complexity of heart sound signals in clinical applications. In response to the above problems, this paper proposes a heart sound classification framework that integrates signal noise denoising and deep learning feature learning. First of all, the soft threshold noise reduction and level-dependent threshold methods based on wavelet transform are studied, and further compared with the noise reduction method based on empirical mode decomposition (EMD). Through quantitative evaluation such as Signal-to-Noise Ratio (SNR), Mean Squared Error (MSE) and Correlation Coefficient (CC) The comparison results of the index show that the EMD noise reduction method and the layered threshold wavelet noise reduction can better retain the morphological characteristics of the basic heart sound components such as S1 and S2 in the heart sound signal while effectively suppressing noise. After completing the noise reduction of the heart sound signal, comparing the single modal input and multi-modal input, the multi-mode has better performance. The classification effect of the PCG signal is evaluated by the model through the four key indicators of Accuracy with 0.82, Specificity with 0.785, Sensitivity with 0.845 and Score with 0.815.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">EMD denoising-assisted deep CNN for automated heart sound classification</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-04-07T09:01:01.920Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8999f485-6003-4a16-87ba-1e1da377afef">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>EMD denoising-assisted deep CNN for automated heart sound classification&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Cao, Shuwen&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Phonocardiogram (PCG) analysis provides a non-invasive and low-cost technical means for cardiovascular disease screening, but it is often limited by noise interference and high non-stationarity and complexity of heart sound signals in clinical applications. In response to the above problems, this paper proposes a heart sound classification framework that integrates signal noise denoising and deep learning feature learning. First of all, the soft threshold noise reduction and level-dependent threshold methods based on wavelet transform are studied, and further compared with the noise reduction method based on empirical mode decomposition (EMD). Through quantitative evaluation such as Signal-to-Noise Ratio (SNR), Mean Squared Error (MSE) and Correlation Coefficient (CC) The comparison results of the index show that the EMD noise reduction method and the layered threshold wavelet noise reduction can better retain the morphological characteristics of the basic heart sound components such as S1 and S2 in the heart sound signal while effectively suppressing noise. After completing the noise reduction of the heart sound signal, comparing the single modal input and multi-modal input, the multi-mode has better performance. The classification effect of the PCG signal is evaluated by the model through the four key indicators of Accuracy with 0.82, Specificity with 0.785, Sensitivity with 0.845 and Score with 0.815.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>