<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T13:05:42Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/212752" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/212752</identifier><datestamp>2026-04-08T11:52:13Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Feng, Liuhuiqi</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Chan Pak Kwong</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">epkchan@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-04-07T23:56:23Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-04-07T23:56:23Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/212752</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">This dissertation presents a Sample and Hold circuit which can be applied in Analog to Digital converter (ADC). The Sample-and-Hold Amplifier (SHA) incorporates fully differential topology, bootstrapping technique, injection nulling switch (INS), and the concept of bottom plate sampling to realize high precision. By using TSMC 40nm technology, a resolution of 12 bit has been obtained at a sampling rate of 50MHz and an input swing of 0.8Vpp. In addition, Spurious Free Dynamic Range (SFDR) reaches 74dB with Total Harmonic Distortion (THD) lower than -70dB at an input frequency of 25.1MHz. The simulation results have shown that the proposed design has high SFDR and SNR while the THD is low, making it feasible as the front end of high precision ADC, especially for Pipelined ADC application.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="relation">ISM-DISS-04971</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Analog-to-digital converter</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Sample and hold circuit</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Injection nulling</dim:field>
   <dim:field mdschema="dc" element="title">Design of a precision CMOS sample-and-hold circuit</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-04-07T09:18:49.284Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="bf442f21-2bf8-4c56-ab2b-ec52b5958592">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Design of a precision CMOS sample-and-hold circuit&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Feng, Liuhuiqi&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>This dissertation presents a Sample and Hold circuit which can be applied in Analog to Digital converter (ADC). The Sample-and-Hold Amplifier (SHA) incorporates fully differential topology, bootstrapping technique, injection nulling switch (INS), and the concept of bottom plate sampling to realize high precision. By using TSMC 40nm technology, a resolution of 12 bit has been obtained at a sampling rate of 50MHz and an input swing of 0.8Vpp. In addition, Spurious Free Dynamic Range (SFDR) reaches 74dB with Total Harmonic Distortion (THD) lower than -70dB at an input frequency of 25.1MHz. The simulation results have shown that the proposed design has high SFDR and SNR while the THD is low, making it feasible as the front end of high precision ADC, especially for Pipelined ADC application.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>