<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T08:23:13Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/212874" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/212874</identifier><datestamp>2026-04-13T11:36:26Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Cen, Binbin</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Poenar Daniel Puiu</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="research" authority="f07c4a02-f85a-48a2-b382-a70ee4e636d1" confidence="500">Asian Business Case Centre</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">EPDPuiu@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-04-13T06:28:53Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-04-13T06:28:53Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/212874</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Single-cell separation and dispensing technology serves as a core tool for analyzing cellular heterogeneity and advancing precision medicine and single-cell multimodal research. Ultra-low volume precision dispensing is essential for biochemical testing using microarrays. Addressing existing equipment limitations such as low cell viability, limited sorting throughput, poor compatibility, and complex operation, this research designed a fully automated single-cell separation and dispensing device integrating optical recognition, microfluidic manipulation, acoustic actuation, and precision motion control which adopts a six-module collaborative architecture. The circuit system ensures stable multi-module power supply and precise signal drive. The mechanical structure guarantees dispensing accuracy through micrometer-level motion platforms and vibration damping design. The control system achieves full-process automation based on C programming language bottom-layer drivers and Python top-layer decisions. Performance testing demonstrates efficient sorting of particles ranging from 2 to 70 μm(covering bacteria to mammalian cells), achieving 90% accuracy in single-cell dispensing while maintaining cell viability above 95%. The device operates at a throughput of 30 cells/s and is compatible with standard 96/384/1536-well plates and custom microfluidic chips. This device offers a low-cost, high-performance technical solution for applications including multiplexed biosensing, single-cell genomics, and clinical rare cell detection, demonstrating significant academic value and industrialization potential.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Design and implementation of a single-cell separation and dispensing device based on microfluidic-acoustic synergy</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-04-10T11:57:28.230Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="1cbb25b7-ea1d-4880-96b4-1d69aa5e38f4">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Design and implementation of a single-cell separation and dispensing device based on microfluidic-acoustic synergy&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Cen, Binbin&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Single-cell separation and dispensing technology serves as a core tool for analyzing cellular heterogeneity and advancing precision medicine and single-cell multimodal research. Ultra-low volume precision dispensing is essential for biochemical testing using microarrays. Addressing existing equipment limitations such as low cell viability, limited sorting throughput, poor compatibility, and complex operation, this research designed a fully automated single-cell separation and dispensing device integrating optical recognition, microfluidic manipulation, acoustic actuation, and precision motion control which adopts a six-module collaborative architecture. The circuit system ensures stable multi-module power supply and precise signal drive. The mechanical structure guarantees dispensing accuracy through micrometer-level motion platforms and vibration damping design. The control system achieves full-process automation based on C programming language bottom-layer drivers and Python top-layer decisions. Performance testing demonstrates efficient sorting of particles ranging from 2 to 70 μm(covering bacteria to mammalian cells), achieving 90% accuracy in single-cell dispensing while maintaining cell viability above 95%. The device operates at a throughput of 30 cells/s and is compatible with standard 96/384/1536-well plates and custom microfluidic chips. This device offers a low-cost, high-performance technical solution for applications including multiplexed biosensing, single-cell genomics, and clinical rare cell detection, demonstrating significant academic value and industrialization potential.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>