<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-27T10:25:12Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/213887" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/213887</identifier><datestamp>2026-04-19T11:10:56Z</datestamp><setSpec>com_10356_986</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2218</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Dong, Junhong</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Chen I-Ming</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="50c1ae5d-dbc2-4261-8647-8a6bc78fd13d" confidence="500">School of Mechanical and Aerospace Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">Chen I-Ming (Prof) &lt;MICHEN@ntu.edu.sg></dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-04-18T12:53:14Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-04-18T12:53:14Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/213887</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">In unstructured medical environments, the automated management of surgical instruments 
represents a key frontier in humanoid robot applications. However, surgical instruments are usually 
made of stainless steel, and their highly reflective characteristics lead to serious data loss and noise 
generated by active depth sensors, coupled with the random stacking and mutual occlusion of 
instruments in the cleaning and disinfection tray, which makes traditional machine vision and 
grasping strategies very challenging.
In this paper, a complete real-time visual perception and sorting system is proposed for the 
Unitree G1 humanoid robot platform. Firstly, this paper proposes a visual enhancement scheme 
based on "Copy-Paste" enhancement combined with an instance segmentation training strategy 
and active light source tuning.
A time-domain histogram filter is designed to reconstruct high signal-to-noise ratio depth 
information at the pixel level. Secondly, limited by the computing power of the core computer of 
the robot platform, in order to solve the hierarchical judgment problem of stacked objects, this 
paper abandons the deep learning relationship network with high computing power, and instead 
designs a lightweight reasoning algorithm based on the fusion of sparse depth statistical features 
(10% quantile strategy) and semantic confidence. Finally, in view of the strict requirements of 
humanoid robots for the real-time performance of control loops, this paper verifies the rapid 
grasping pose generation method based on PCA. Experimental results show that the sorting success 
rate of the system in complex stacking scenarios reaches more than 92%, and the end-to-end 
processing delay is controlled within 30 ms, which is significantly better than the traditional point 
cloud registration method, providing a reliable engineering paradigm for the actual deployment of 
humanoid robots in medical logistics.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Research on a real-time stacking and sorting system of surgical instruments for humanoid robots</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-04-18T06:06:05.016Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="07e0fbd4-01c8-4e6e-8f89-09974502729a">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Research on a real-time stacking and sorting system of surgical instruments for humanoid robots&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors&gt;
      	&lt;Author>
        	&lt;DisplayName>Dong, Junhong&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>In unstructured medical environments, the automated management of surgical instruments 
represents a key frontier in humanoid robot applications. However, surgical instruments are usually 
made of stainless steel, and their highly reflective characteristics lead to serious data loss and noise 
generated by active depth sensors, coupled with the random stacking and mutual occlusion of 
instruments in the cleaning and disinfection tray, which makes traditional machine vision and 
grasping strategies very challenging.
In this paper, a complete real-time visual perception and sorting system is proposed for the 
Unitree G1 humanoid robot platform. Firstly, this paper proposes a visual enhancement scheme 
based on &amp;quot;Copy-Paste&amp;quot; enhancement combined with an instance segmentation training strategy 
and active light source tuning.
A time-domain histogram filter is designed to reconstruct high signal-to-noise ratio depth 
information at the pixel level. Secondly, limited by the computing power of the core computer of 
the robot platform, in order to solve the hierarchical judgment problem of stacked objects, this 
paper abandons the deep learning relationship network with high computing power, and instead 
designs a lightweight reasoning algorithm based on the fusion of sparse depth statistical features 
(10% quantile strategy) and semantic confidence. Finally, in view of the strict requirements of 
humanoid robots for the real-time performance of control loops, this paper verifies the rapid 
grasping pose generation method based on PCA. Experimental results show that the sorting success 
rate of the system in complex stacking scenarios reaches more than 92%, and the end-to-end 
processing delay is controlled within 30 ms, which is significantly better than the traditional point 
cloud registration method, providing a reliable engineering paradigm for the actual deployment of 
humanoid robots in medical logistics.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>