<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T16:21:55Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/214366" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/214366</identifier><datestamp>2026-11-27T18:08:17Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Zhang, Zheming</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Siek Liter</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">ELSIEK@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-04-24T05:04:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-04-24T05:04:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/214366</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Magnetic Resonance Imaging technology has become a pillar tool for clinical diagnosis by virtue of its core advantages of no ionizing radiation and excellent soft tissue resolution. However, the scanning requirement that patients stay in a closed bore for 10–30 minutes is prone to inducing negative emotions such as claustrophobia and anxiety, which in turn lead to motion artifacts and repeated scans. Meanwhile, the urgent demand for efficient human-machine interaction in the medical industry’s &amp;quot;unattended scanning workflow&amp;quot; renders traditional light environment solutions—only capable of basic lighting—increasingly inadequate. As a core solution tailored to the closed bore space of MRI systems, bore projection can directly regulate patients’ visual perception through dynamic content (e.g., natural landscapes, children’s animations), alleviate negative emotions and improve cooperation among special populations via non-pharmaceutical means, and carry functional content such as breathing guidance and scan progress visualization. This irreplaceable value makes it the key to addressing clinical pain points. Nevertheless, existing technical attempts at bore projection are constrained by magnetic compatibility challenges, fanless heat dissipation bottlenecks, and bore space limitations in strong MRI magnetic fields, hindering safe integration with MRI systems. Targeted technical breakthroughs are urgently required. This study focuses on MRI bore scenarios, aiming to develop a bore projection system featuring both magnetic compatibility and functional integration. It fills the technical gap in MRI bore projection technology and addresses the defects of traditional equipment, such as large volume and strong interference. By means of non-pharmaceutical interventions, the system optimizes patient experience and ensures imaging quality, while providing core HMI support for the unattended MRI scanning
workflow, thus demonstrating significant clinical value and promotion potentia</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master&amp;apos;s degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Projection system design for magnetic resonance clinical guidance</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-04-24T01:59:59.295Z</dim:field>
   <dim:field mdschema="datacite" element="rights">embargo</dim:field>
   <dim:field mdschema="datacite" element="available">2028-04-24</dim:field>embargoembargo<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="b6c3408e-2835-4a2d-a76a-28863835a47f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Projection system design for magnetic resonance clinical guidance&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Zhang, Zheming&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Magnetic Resonance Imaging technology has become a pillar tool for clinical diagnosis by virtue of its core advantages of no ionizing radiation and excellent soft tissue resolution. However, the scanning requirement that patients stay in a closed bore for 10–30 minutes is prone to inducing negative emotions such as claustrophobia and anxiety, which in turn lead to motion artifacts and repeated scans. Meanwhile, the urgent demand for efficient human-machine interaction in the medical industry’s &amp;quot;unattended scanning workflow&amp;quot; renders traditional light environment solutions—only capable of basic lighting—increasingly inadequate. As a core solution tailored to the closed bore space of MRI systems, bore projection can directly regulate patients’ visual perception through dynamic content (e.g., natural landscapes, children’s animations), alleviate negative emotions and improve cooperation among special populations via non-pharmaceutical means, and carry functional content such as breathing guidance and scan progress visualization. This irreplaceable value makes it the key to addressing clinical pain points. Nevertheless, existing technical attempts at bore projection are constrained by magnetic compatibility challenges, fanless heat dissipation bottlenecks, and bore space limitations in strong MRI magnetic fields, hindering safe integration with MRI systems. Targeted technical breakthroughs are urgently required. This study focuses on MRI bore scenarios, aiming to develop a bore projection system featuring both magnetic compatibility and functional integration. It fills the technical gap in MRI bore projection technology and addresses the defects of traditional equipment, such as large volume and strong interference. By means of non-pharmaceutical interventions, the system optimizes patient experience and ensures imaging quality, while providing core HMI support for the unattended MRI scanning
workflow, thus demonstrating significant clinical value and promotion potentia&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>