<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T21:42:36Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/214611" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/214611</identifier><datestamp>2026-05-04T12:07:52Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Chen, Menghan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Wen Bihan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">bihan.wen@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-05-04T06:51:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-05-04T06:51:26Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/214611</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Magnetic Resonance Imaging (MRI) is a widely used non-invasive imaging technique, but its long acquisition time remains a major limitation. Accelerated MRI reduces scan time by undersampling k-space data, resulting in an ill-posed reconstruction problem. While deep learning methods have achieved strong performance, model-based approaches that combine physical constraints with learned priors still face challenges in generalizing across different sampling patterns and acceleration factors.

This dissertation addresses the generalization problem in model-based MRI reconstruction using the Progressive Divide-and-Conquer (PDAC) framework with a HUMUS-Net backbone. Two strategies are investigated: mixed-acceleration training, which exposes the model to diverse sampling patterns, and mask-aware FiLM conditioning, which incorporates sampling mask information into the network.

Experiments on the Stanford 2D Fast Spin Echo dataset with acceleration factors of 4 times, 6 times, and 8 times show that mixed-acceleration training significantly improves generalization, particularly at higher acceleration. In contrast, FiLM conditioning provides limited benefits, and combining both methods does not yield further improvement.

Overall, the results highlight the importance of training data diversity for improving generalization and suggest that conditioning mechanisms require careful design for effective performance.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">MRI reconstruction</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Generalization</dim:field>
   <dim:field mdschema="dc" element="title">Model-based deep learning for MRI reconstruction</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-04-30T03:30:13.106Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="f30c5e49-2999-41d4-83db-5b05b1a5fd9d">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Model-based deep learning for MRI reconstruction&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Chen, Menghan&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>Magnetic Resonance Imaging (MRI) is a widely used non-invasive imaging technique, but its long acquisition time remains a major limitation. Accelerated MRI reduces scan time by undersampling k-space data, resulting in an ill-posed reconstruction problem. While deep learning methods have achieved strong performance, model-based approaches that combine physical constraints with learned priors still face challenges in generalizing across different sampling patterns and acceleration factors.

This dissertation addresses the generalization problem in model-based MRI reconstruction using the Progressive Divide-and-Conquer (PDAC) framework with a HUMUS-Net backbone. Two strategies are investigated: mixed-acceleration training, which exposes the model to diverse sampling patterns, and mask-aware FiLM conditioning, which incorporates sampling mask information into the network.

Experiments on the Stanford 2D Fast Spin Echo dataset with acceleration factors of 4 times, 6 times, and 8 times show that mixed-acceleration training significantly improves generalization, particularly at higher acceleration. In contrast, FiLM conditioning provides limited benefits, and combining both methods does not yield further improvement.

Overall, the results highlight the importance of training data diversity for improving generalization and suggest that conditioning mechanisms require careful design for effective performance.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>