<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T00:23:01Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/214957" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/214957</identifier><datestamp>2026-05-13T11:30:21Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Chen, Junyu</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Yun Yang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">yun.yang@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-05-13T08:49:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-05-13T08:49:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/214957</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">This paper investigates the output limitations of conventional multidimensional wireless power transfer (WPT) systems under spatial weak-coupling conditions. Based on the LCC-Series (LCC-S) compensation network, a novel primary-side asymmetric current optimization control strategy is proposed. Through theoretical derivation, the output power and transmission efficiency of the proposed method are analyzed and compared with the traditional normalization-based strategy under both omnidirectional and directional modes in two-dimensional (2-D) and three-dimensional (3-D) spaces. Theoretical analysis reveals advantages of the proposed strategy at specific spatial angles. To validate the theoretical model, 2-D and 3-D WPT system simulation models were built using PSIM. The simulation results, including output power, efficiency envelopes, and peak positions and values, which closely match the theoretical predictions, verifying the effectiveness and accuracy of the proposed current control strategy. In addition, the system’s output  performance under various multi-load conditions is briefly evaluated, highlighting the appropriate control approaches for different scenarios.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="relation">ISM-DISS-05726</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Multidimensional</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Wireless power transfer (WPT)</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">LCC-S</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Current  optimization</dim:field>
   <dim:field mdschema="dc" element="subject" qualifier="keywords">Control strategy</dim:field>
   <dim:field mdschema="dc" element="title">Implementation of a high-frequency spatial charging system — control design</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-05-12T09:26:19.656Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="6202b96b-3fa6-48ac-b992-c5a2bad5fa73">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Implementation of a high-frequency spatial charging system — control design&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Chen, Junyu&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>This paper investigates the output limitations of conventional multidimensional wireless power transfer (WPT) systems under spatial weak-coupling conditions. Based on the LCC-Series (LCC-S) compensation network, a novel primary-side asymmetric current optimization control strategy is proposed. Through theoretical derivation, the output power and transmission efficiency of the proposed method are analyzed and compared with the traditional normalization-based strategy under both omnidirectional and directional modes in two-dimensional (2-D) and three-dimensional (3-D) spaces. Theoretical analysis reveals advantages of the proposed strategy at specific spatial angles. To validate the theoretical model, 2-D and 3-D WPT system simulation models were built using PSIM. The simulation results, including output power, efficiency envelopes, and peak positions and values, which closely match the theoretical predictions, verifying the effectiveness and accuracy of the proposed current control strategy. In addition, the system’s output  performance under various multi-load conditions is briefly evaluated, highlighting the appropriate control approaches for different scenarios.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>