<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T21:37:07Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/215214" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/215214</identifier><datestamp>2026-05-18T12:13:39Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Xu, Yuhang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Yun Yang</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="500">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">yun.yang@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-05-18T07:03:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-05-18T07:03:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/215214</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">This study investigates the application of a 13.56 MHz wireless power transfer (WPT) system for implantable medical devices, focusing on its engineering feasibility and biological safety. A comparative analysis of different frequency bands is first conducted, and a flexible PCB-based planar circular receiver coil structure is proposed. In vitro human cell experiments are then performed to evaluate the effects 
of high-frequency magnetic field exposure on cell proliferation and morphology. The results show no statistically significant adverse effects under the investigated exposure conditions. Furthermore, finite element–based electromagnetic simulations are carried out to analyze magnetic field distribution and key electromagnetic parameters of the receiver coil. The findings indicate rapid spatial attenuation of the magnetic field and confirm compliance with basic electromagnetic safety considerations. Overall, the proposed high-frequency wireless power solution demonstrates engineering feasibility and preliminary biological safety for implantable applications.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Engineering</dim:field>
   <dim:field mdschema="dc" element="title">Research on flexible PCB-based wireless power receivers in spatial wireless power transfer systems</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-05-13T01:49:44.206Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="c8eed293-03d8-47d5-b62a-ee8e635c94d8">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Research on flexible PCB-based wireless power receivers in spatial wireless power transfer systems&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Xu, Yuhang&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Engineering&lt;/Keyword>
   	&lt;Abstract>This study investigates the application of a 13.56 MHz wireless power transfer (WPT) system for implantable medical devices, focusing on its engineering feasibility and biological safety. A comparative analysis of different frequency bands is first conducted, and a flexible PCB-based planar circular receiver coil structure is proposed. In vitro human cell experiments are then performed to evaluate the effects 
of high-frequency magnetic field exposure on cell proliferation and morphology. The results show no statistically significant adverse effects under the investigated exposure conditions. Furthermore, finite element–based electromagnetic simulations are carried out to analyze magnetic field distribution and key electromagnetic parameters of the receiver coil. The findings indicate rapid spatial attenuation of the magnetic field and confirm compliance with basic electromagnetic safety considerations. Overall, the proposed high-frequency wireless power solution demonstrates engineering feasibility and preliminary biological safety for implantable applications.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>