<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T12:40:58Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/215810" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/215810</identifier><datestamp>2026-05-27T04:25:23Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author">Li, Haoxuan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor">Andy Khong W H</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisoremail">AndyKhong@ntu.edu.sg</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2026-05-25T23:10:22Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2026-05-25T23:10:22Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2026</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/215810</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">This dissertation presents a bidirectional sensor fusion system that extends the reliability of mmWave radar-based indoor human body tracking by integrating a TI 60GHz FMCW radar with an Intel RealSense depth camera. The radar subsystem implements a multi-level DBSCAN clustering pipeline with SNR-stratified parameters, cluster merging, minimum point count filtering, and possibility-matrixbased single-target tracking. The vision subsystem employs YOLOv11-Pose for real-time 17-keypoint skeleton detection and computes a robust person centre from the heart point and hip joints using the RealSense depth stream. The core contribution is a bidirectional late-fusion framework comprising two complementary mechanisms. First, a camera-guided spatial gating mechanism maps the camera-detected person position into the radar coordinate space and defines an asymmetric disk-shaped acceptance region (lateral radius 0.3m, depth radius 0.5m) that filters phantom radar clusters caused by background clutter and multipath reflections. Second, a radar-based depth correction method computes the offset between the radar range measurement and the camera depth at the heart point and propagates this correction to all skeleton keypoints, compensating for the structured-light camera’s distance-dependent depth bias. The two subsystems communicate via a lightweight TCP bridge operating asynchronously across separate software environments, requiring no external dependencies and supporting automatic reconnection. The system is designed for graceful degradation: each sensor operates independently when the other is unavailable, and the fusion layer is purely additive. Experimental evaluation in an indoor environment demonstrates that cameraguided gating reduces phantom detections by 84.3%, tracking dropouts during lateral movement by 83.3%, and tracking dropouts during body rotation by 62.5%. Radar-based depth correction reduces the mean absolute depth error of skeleton keypoints by 67.4%, from 0.215m to 0.070m, with the greatest improvement at longer ranges. These results are achieved without formal extrinsic calibration or training data, confirming that lightweight geometric fusion can substantially extend the reliability of mmWave radar tracking in indoor environments.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Master's degree</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en</dim:field>
   <dim:field mdschema="dc" element="publisher">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject">Computer and Information Science</dim:field>
   <dim:field mdschema="dc" element="title">Extending reliability of mmWave radar tracking and detection via fusion with camera</dim:field>
   <dim:field mdschema="dc" element="type">Thesis-Master by Coursework</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="dspace" element="workflow" qualifier="startDateTime">2026-05-25T12:09:42.563Z</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="a786fe3c-6a1a-4045-bd00-705cfe71304f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Extending reliability of mmWave radar tracking and detection via fusion with camera&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2026&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Li, Haoxuan&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Nanyang Technological University&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>Computer and Information Science&lt;/Keyword>
   	&lt;Abstract>This dissertation presents a bidirectional sensor fusion system that extends the reliability of mmWave radar-based indoor human body tracking by integrating a TI 60GHz FMCW radar with an Intel RealSense depth camera. The radar subsystem implements a multi-level DBSCAN clustering pipeline with SNR-stratified parameters, cluster merging, minimum point count filtering, and possibility-matrixbased single-target tracking. The vision subsystem employs YOLOv11-Pose for real-time 17-keypoint skeleton detection and computes a robust person centre from the heart point and hip joints using the RealSense depth stream. The core contribution is a bidirectional late-fusion framework comprising two complementary mechanisms. First, a camera-guided spatial gating mechanism maps the camera-detected person position into the radar coordinate space and defines an asymmetric disk-shaped acceptance region (lateral radius 0.3m, depth radius 0.5m) that filters phantom radar clusters caused by background clutter and multipath reflections. Second, a radar-based depth correction method computes the offset between the radar range measurement and the camera depth at the heart point and propagates this correction to all skeleton keypoints, compensating for the structured-light camera’s distance-dependent depth bias. The two subsystems communicate via a lightweight TCP bridge operating asynchronously across separate software environments, requiring no external dependencies and supporting automatic reconnection. The system is designed for graceful degradation: each sensor operates independently when the other is unavailable, and the fusion layer is purely additive. Experimental evaluation in an indoor environment demonstrates that cameraguided gating reduces phantom detections by 84.3%, tracking dropouts during lateral movement by 83.3%, and tracking dropouts during body rotation by 62.5%. Radar-based depth correction reduces the mean absolute depth error of skeleton keypoints by 67.4%, from 0.215m to 0.070m, with the greatest improvement at longer ranges. These results are achieved without formal extrinsic calibration or training data, confirming that lightweight geometric fusion can substantially extend the reliability of mmWave radar tracking in indoor environments.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>