<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-27T16:52:39Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/3136" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/3136</identifier><datestamp>2025-05-14T18:04:58Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Phyu Mar Myint.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Birlasekaran, Sivaswamy</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-09-17T09:23:00Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-09-17T09:23:00Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/3136</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A transformer is one of the most important units in power network. For reliable operation of network, diagnosis of developing faults in transformer is very important. This project presents a novel and sensitive frequency response analysis (FRA) technique for identifying the winding faults in power apparatus. This technique is a suitable off-line diagnostic method for identifying electrical and mechanical faults of a transformer. The main objective of this project is to investigate the applicability of this predictive maintenance technique to identify the level of winding faults in power transformer and to characterize the transformer in a frequency plane for safe operation.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">Nanyang Technological University</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">DRNTU::Engineering::Electrical and electronic engineering::Electric power</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Identification of winding faults in transformers</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="author">DRNTU::Engineering::Electrical and electronic engineering::Electric power::Auxiliaries, applications and electric industries.</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="3cc21092-6c32-4079-bb38-b5f7b8100501">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Identification of winding faults in transformers&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Phyu Mar Myint.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering::Electric power&lt;/Keyword>
   	&lt;Abstract>A transformer is one of the most important units in power network. For reliable operation of network, diagnosis of developing faults in transformer is very important. This project presents a novel and sensitive frequency response analysis (FRA) technique for identifying the winding faults in power apparatus. This technique is a suitable off-line diagnostic method for identifying electrical and mechanical faults of a transformer. The main objective of this project is to investigate the applicability of this predictive maintenance technique to identify the level of winding faults in power transformer and to characterize the transformer in a frequency plane for safe operation.&lt;/Abstract>