<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T01:58:09Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/39161" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/39161</identifier><datestamp>2025-05-14T15:44:11Z</datestamp><setSpec>com_10356_984</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2206</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Elangovan Karthikeyan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en_US">Cai Wenjian</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en_US" authority="85c7c066-467c-42e1-86e3-b953777526f2" confidence="600">School of Electrical and Electronic Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2010-05-21T04:46:37Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2010-05-21T04:46:37Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2007</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/10356/39161</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">97 p.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Most of the controllers commissioned in industrial areas are of Proportional-integralderivative (PID) type. Tuning a proper PID controller requires an accurate model of a Process and an effective controller design rule. The tuning procedure can be a timeconsuming, expensive and difficult task. This is also true to Heating, Ventilating, and Air-conditioning (HVAC) systems. Although many improved PID design methods are proposed, the Ziegler and Nichols (Z-N) methods are still adopted by many HVAC control engineers. The Z-N methods have been most commonly used in HVAC systems. It has sometimes been difficult to compensate fully for load disturbance and to keep controlled variables close to set point values within the prescribed range, have the shortcomings such as long testing time, limited control performance.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Master of Science (Computer Control and Automation)</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_us">DRNTU::Engineering::Electrical and electronic engineering::Electronic systems::Signal processing</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Advance duct pressure control for HVAC system</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="datacite" element="rights">restricted</dim:field>restrictedrestricted<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="07ed7c4b-8292-4255-809c-5b63b253a73a">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Advance duct pressure control for HVAC system&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2007&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Elangovan Karthikeyan&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Electrical and electronic engineering::Electronic systems::Signal processing&lt;/Keyword>
   	&lt;Abstract>Most of the controllers commissioned in industrial areas are of Proportional-integralderivative (PID) type. Tuning a proper PID controller requires an accurate model of a Process and an effective controller design rule. The tuning procedure can be a timeconsuming, expensive and difficult task. This is also true to Heating, Ventilating, and Air-conditioning (HVAC) systems. Although many improved PID design methods are proposed, the Ziegler and Nichols (Z-N) methods are still adopted by many HVAC control engineers. The Z-N methods have been most commonly used in HVAC systems. It has sometimes been difficult to compensate fully for load disturbance and to keep controlled variables close to set point values within the prescribed range, have the shortcomings such as long testing time, limited control performance.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>