<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-28T06:23:33Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/39358" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/39358</identifier><datestamp>2026-11-25T21:19:18Z</datestamp><setSpec>com_10356_982</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2152</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en">Edward Anggadjaja</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en">Teng Susanto</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en" authority="a6dec9ca-977d-49d3-af9e-2924bad6cbb7" confidence="600">School of Civil and Environmental Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned" lang="en">2010-05-21T05:23:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available" lang="en">2010-05-21T05:23:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en">2007</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2007</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation" lang="en">Edward Anggadjaja. (2007). Shear capacity of slab-column connections under gravity and biaxial cyclic lateral loading. Doctoral thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/39358</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi" lang="en">10.32657/10356/39358</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Reinforced concrete flat plate structures have been widely used for residential and office buildings around the world due to their economical and aesthetical advantages over the conventional beam and slab system. However, the transfer of shear and unbalanced moment at the slab-column connections may result in a sudden and brittle punching failure at these connections. Thus, the economy of the flat plate structure depends on the degree to which the ultimate strength of the slab-column connections can be predicted and utilized.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en">Doctor of Philosophy (CEE)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en">329 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">DRNTU::Engineering::Civil engineering::Structures and design</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Shear capacity of slab-column connections under gravity and biaxial cyclic lateral loading</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-25T21:19:17Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-14T00:44:56Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="a965b94a-a7cc-4bba-81dc-4f3ab8aea0e2">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Shear capacity of slab-column connections under gravity and biaxial cyclic lateral loading&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2007&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/39358&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Edward Anggadjaja&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Engineering::Civil engineering::Structures and design&lt;/Keyword>
   	&lt;Abstract>Reinforced concrete flat plate structures have been widely used for residential and office buildings around the world due to their economical and aesthetical advantages over the conventional beam and slab system. However, the transfer of shear and unbalanced moment at the slab-column connections may result in a sudden and brittle punching failure at these connections. Thus, the economy of the flat plate structure depends on the degree to which the ultimate strength of the slab-column connections can be predicted and utilized.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>