<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T13:09:44Z</responseDate><request verb="GetRecord" identifier="oai:dr.ntu.edu.sg:10356/41683" metadataPrefix="dim">https://dr.ntu.edu.sg/server/oai/request</request><GetRecord><record><header><identifier>oai:dr.ntu.edu.sg:10356/41683</identifier><datestamp>2026-11-25T21:53:14Z</datestamp><setSpec>com_10356_22</setSpec><setSpec>com_10356_19</setSpec><setSpec>com_10356_11</setSpec><setSpec>col_10356_2140</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en">Meer Saiful Hassan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="supervisor" lang="en">Lau Wai Man Raymond</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="school" lang="en" authority="e2ab4d89-898f-4947-b23b-5fa99c4c18c3" confidence="600">School of Chemical and Biomedical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned" lang="en">2010-08-05T01:04:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available" lang="en">2010-08-05T01:04:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en">2010</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en">2010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="citation" lang="en">Meer, S. H. (2010). Formulation of particles for pulmonary drug delivery. Doctoral thesis, Nanyang Technological University, Singapore.</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri" lang="en">https://hdl.handle.net/10356/41683</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="doi" lang="en">10.32657/10356/41683</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en">Pulmonary drug delivery has become an attractive route of drug administration to the human body for the treatment of lung diseases and a number of systemic applications. Dry powder inhalation (DPI) is considered as the most appropriate aerosol therapeutics in terms of delivery efficiency, patient compliance and environmental issue. Successful delivery of the dry powder formulation to the deep lung requires proper understanding of the factor influencing particle deposition. Improvement of the drug formulation characteristics is the most convenient way to control delivery performance. In this study, the effect of shape and morphology of dry particles for inhalation is investigated. The optimum design of micro-particle for better delivery performance is determined.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en">DOCTOR OF PHILOSOPHY (SCBE)</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en">237 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en">en</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">DRNTU::Science::Medicine::Pharmacy::Pharmaceutical technology</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en">DRNTU::Engineering::Chemical engineering::Biotechnology</dim:field>
   <dim:field mdschema="dc" element="title" lang="en">Formulation of particles for pulmonary drug delivery</dim:field>
   <dim:field mdschema="dc" element="type" lang="en">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="scopus">2026-11-25T21:53:13Z</dim:field>
   <dim:field mdschema="cris" element="lastimport" qualifier="wos">2025-08-12T00:18:41Z</dim:field>
   <dim:field mdschema="datacite" element="rights">open.access</dim:field>open.accessopen.access<dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="83272331-74a4-4380-95db-31bc6b43b153">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>Formulation of particles for pulmonary drug delivery&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2010&lt;/PublicationDate>
   	&lt;DOI>10.32657/10356/41683&lt;/DOI>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Meer Saiful Hassan&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;Keyword>DRNTU::Science::Medicine::Pharmacy::Pharmaceutical technology&lt;/Keyword>
    &lt;Keyword>DRNTU::Engineering::Chemical engineering::Biotechnology&lt;/Keyword>
   	&lt;Abstract>Pulmonary drug delivery has become an attractive route of drug administration to the human body for the treatment of lung diseases and a number of systemic applications. Dry powder inhalation (DPI) is considered as the most appropriate aerosol therapeutics in terms of delivery efficiency, patient compliance and environmental issue. Successful delivery of the dry powder formulation to the deep lung requires proper understanding of the factor influencing particle deposition. Improvement of the drug formulation characteristics is the most convenient way to control delivery performance. In this study, the effect of shape and morphology of dry particles for inhalation is investigated. The optimum design of micro-particle for better delivery performance is determined.&lt;/Abstract>